期刊文献+

多焦视网膜电图对近视眼的临床研究 被引量:3

Multifocal electroretinogram in myopia
暂未订购
导出
摘要 目的:测试近视眼患者的多焦视网膜电图的改变。方法:应用美国EDI公司生产的VERISScience4.2多焦视网膜电图检查仪对24例48眼近视患者,22例44眼正常者进行检测,分析其总体和6个环形视网膜区域的反应。结果:近视患者总体和6个环形视网膜区域的反应密度均低于正常者,潜伏期无明显改变。结论:近视患者多焦视网膜电图的反应密度下降,这种改变主要是由于视网膜感受器功能受损所致。 AIM: To measure and compare the difference of multifocal electroretinogram between normal subjects and patients with myopia. METHODS: Twenty-two cases (44 eyes) of normal subjects and twenty-four cases (48 eyes) with myopia were tested with VERIS Science 4.2 made by EDI company of America. All trace grouping waveform and six ring average response were determined. We studied the differences of response densities and latencies between normal and myopic groups. RESULTS:The response densities of all trace grouping waveform and six ring average response in myopia were decreased while the latencies were not changed. CONCLUSION: The response densities of multifocal electroretinogram in myopic eyes were reduced and resulted predominantly from retinal receptors function loss.
机构地区 沧州眼科医院
出处 《国际眼科杂志》 CAS 2010年第2期360-361,共2页 International Eye Science
关键词 多焦视网膜电图 近视眼 视网膜感受器 multifocal electroretinogram myopia retinal receptors
  • 相关文献

参考文献4

  • 1Sutter EE, Tran D. The field topography of ERG components in man. The photopic luminance response. Vision Res 1992 ;32 (3) :433-446.
  • 2Palmowski AM, Sutter EE, Bearse MA, et al. Mapping of retinal function in diabetic retinopathy using the muhifocal electroretinogram. Invest Opbthalmol Vis Sei 1997 ;38 (12) :2586-2595.
  • 3Si Y J, Kishi S, Aoyagi K. Assessment of maeular function by multifocal electroretinogram before and after macular hole surgery. Br J Opbthalmol 1999 ; 83 (4) :420-424.
  • 4Kawabata H, Adachi-Usami E. Muhifocal electroretinogram in myopia. Invest Ophthalmol Vis Sci 1997 ;38 ( 13 ) :2844-2851.

同被引文献46

  • 1石一宁,郑红,陈建华.高度近视眼多焦视网膜电图和传统视觉电生理改变与中低度近视的对比研究[J].国际眼科杂志,2007,7(4):1042-1045. 被引量:6
  • 2吴乐正 吴德正.临床视觉电生理[M].北京:科学出版社,1999.112.
  • 3Ho WC, Kee CS, Chan HH. Myopia Progression in Chil- dren Is Linked with Reduced Foveal mfERG Response[ J]. Invest Ophthalmol Vis Sci, 2012,53 (9) : 5320 - 5325.
  • 4Xie R, Zhou XT, Lu F, etal. Correlation between myopia and major biometric parameters of the eye: a retrospective clinical study[ J ]. Optom Vis Sei, 2009,86 ( 5 ) : E503 - E508.
  • 5Westall CA, Dhaliwal HS, Panton CM, et al. Values of electroretinogram responses according to axial length [ J 1. Doc Ophthalmo1,2001,102 (2) : 115 - 130.
  • 6Risse JF, Saint BP, Boissonnot M, et al. Spatial contrast sen- sitivity in patienis with severe myopia [ J ]. Fr Ophthalmol, 1996,19(4) :271 - 277.
  • 7张秀珍,施天严,俞颂平.高度近视眼与视觉电生理的相关性[C].2011年浙江省眼科学术会议,中国浙江台州,2011.
  • 8Oner A, Gumus K, Arda H. Pattern electroretinographic recordings in eyes with myopia [ J ]. Eye Contact Lens, 2009,35 (5) :238 - 241.
  • 9Sutter E E, Tran D. The field topography of ERG compo- nents in man - I. The photopic luminance response [ J ]. Vision Res, 1992,32 ( 3 ) :433 - 446.
  • 10Vaegan, Buekland L. The spatial distribution of ERG los- ses across the Posterior Pole of glaueomatous eyes in mul- tifocal recordings [ J ]. Aust N Z J Ophthalmol, 1996,24 (2Suppl) :28 - 31.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部