期刊文献+

Development and Validation of a Reverse-phase High Performance Liquid Chromatography Method for Determination of Exenatide in Poly(lactic-co-glycolic acid) Microspheres 被引量:1

Development and Validation of a Reverse-phase High Performance Liquid Chromatography Method for Determination of Exenatide in Poly(lactic-co-glycolic acid) Microspheres
在线阅读 下载PDF
导出
摘要 Exenatide(synthetic exendin-4), which has been approved by the Food and Drug Administration(FDA) for the adjunctive treatment of patients with type 2 diabetes, is an incretin mimetic agent. The development and validation of a RP-HPLC method for the quantification of the exenatide in poly(lactic-co-glycolic acid)(PLGA) microspheres is described. Separation was performed on a C4 column via a mobile phase consisting of ACN:KH2PO4(0.02 tool/L, pH=2.5) gradient elution from 30:70 to 45:55(volume ratio) in 30 min. Multi-diode array detection(DAD) appears to be most appropriate to evaluate the spectral purity of exenatide. The limits of detection and quantification of exenatide were 0.4 and 1.2 μg/mL, respectively. The calibration curve of exenatide was linear in a range of 0.025--0.2 mg/mL with a correlation coefficient of 0.9995. The results of validation study show that this method is specific, accurate(recovery〉95%), precise(RSD〈2.0%) and robust. Exenatide(synthetic exendin-4), which has been approved by the Food and Drug Administration(FDA) for the adjunctive treatment of patients with type 2 diabetes, is an incretin mimetic agent. The development and validation of a RP-HPLC method for the quantification of the exenatide in poly(lactic-co-glycolic acid)(PLGA) microspheres is described. Separation was performed on a C4 column via a mobile phase consisting of ACN:KH2PO4(0.02 tool/L, pH=2.5) gradient elution from 30:70 to 45:55(volume ratio) in 30 min. Multi-diode array detection(DAD) appears to be most appropriate to evaluate the spectral purity of exenatide. The limits of detection and quantification of exenatide were 0.4 and 1.2 μg/mL, respectively. The calibration curve of exenatide was linear in a range of 0.025--0.2 mg/mL with a correlation coefficient of 0.9995. The results of validation study show that this method is specific, accurate(recovery〉95%), precise(RSD〈2.0%) and robust.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第1期33-37,共5页 高等学校化学研究(英文版)
基金 Supported by the Key Projects in the National Science & Technology Pillar Program in the Eleventh Five-year Plan Period,China(No.2008ZX10001-012)
关键词 EXENATIDE Quantification RP-HPLC-DAD PLGA MICROSPHERE Exenatide Quantification RP-HPLC-DAD PLGA Microsphere
  • 相关文献

参考文献22

  • 1Gombotz W. R., Pettit D. K., Bioconjug. Chem., 1995, 6, 332.
  • 2Jeyanthi R., Mehta R. C., Thanoo B. C., et al., J. Microencapsul., 1997, 14, 163.
  • 3Lucke A., Fustella E., Tessmar J., et al., J. Control. Release, 2002, 80, 157.
  • 4Kumar E S., Ramakrishna S., Saini T. R, et al., Pharmazie, 2006, 61, 613.
  • 5Woo B. H., Kostanski J. W., Gebrekidan S., et al., J. Control. Release,2001, 75,307.
  • 6Lam X. M., Duenas E. T., Cleland J. L., J. Pharm. Sci., 2001, 90, 1356.
  • 7Malik D. K., Baboota S., Ahuja A., etal., Curr. Drug. Delia, 2007, 4, 141.
  • 8Xu G., Stoffers D. A., Habener J. F., et al., Diabetes, 1999, 48, 2270.
  • 9Parkes D. G., Pittner R., Jodka C., et al., Metabolism, 2001, 50, 583.
  • 10Tourrel C., Bailbe D., Meile M. J., etal., Diabetes, 2001, 50, 1562.

同被引文献6

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部