摘要
低温地板辐射采暖具有舒适与节能的优点,已被广泛采用于各种场所。低温地板辐射采暖系统设计供回水温度低,而集中供热管网的设计供回水温度是按散热器采暖的要求设定的。从技术上可靠和经济上合理两方面考虑,提出了集中供热系统采用低温地板辐射采暖的供回水设计温度以及热网与低温地板辐射采暖系统的连接方式。
Low-temperature floor panel heating has the advantages of comfort and energy efficiency, and has been widely used in various places. The design supply & return water temperature of low-temperature floor panel heating system is low, while the design supply & return water temperature of central heating pipe network is based on the requirements of radiator heating. Considering both technically reliable and economically reasonable aspects, the supply & return water design temperature of central heating system used low-temperature floor panel is proposed, as well as the connection mode between the heat supply network and the low-temperature .floor panel heating system.