期刊文献+

不同b值MR扩散成像技术对急性脑梗死的诊断价值比较 被引量:1

Application of MR Diffusion Weighted Imaging with Different b Values in Acute Cerebral Infarction
暂未订购
导出
摘要 目的:探讨不同b值磁共振扩散成像(DWI)技术对急性脑梗死的诊断价值。方法:分析、比较116例急性脑梗死患者的b=1000 s/mm2和b=2000 s/mm2DWI图像、常规T2加权像(T2WI)和T2加权压水像(T2WI-FLAIR)。结果:b=2000 DWI图像对脑梗死病灶的显示明显好于b=1000 DWI图像(P<0.05)。结论:高b值DWI可以更敏感地发现脑梗死病灶。 Objective:To explore the value of diffusion weighted imaging(DWI) with different b values in diagnosing acute cerebral infarction.Methods: Two weightings(b=1000,2000 s/mm2) were applied in 116 acute cerebral infarction patients in DWI and the T2WI and T2WI-FLAIR imaging scans were performed as well.Results: When compared with the DWI image scanning with low b value(b=1000 s/mm2),DWI image scanning with high b value(b=2000 s/mm2) can more sensitively reveal infarcted lesions in patients of acute cerebral infarction in early stage(P0.05).Conclusion: Acute cerebral infarction can be demonstrated earlier and more clearly by the images of DWI with high b values.
出处 《神经损伤与功能重建》 2009年第6期405-407,共3页 Neural Injury and Functional Reconstruction
关键词 B值 MR扩散成像技术 脑梗死 high b value diffusion weighing imaging cerebral infarction
  • 相关文献

参考文献12

  • 1冯凯琳,董少义,顾欣,袁滨,付维林,袁飞.磁共振扩散加权成像在急性脑梗死诊断中的应用[J].武警医学院学报,2007,16(4):357-361. 被引量:5
  • 2刘建滨,李建策,戴敏红,丘清亮.磁共振弥散加权成像在脑部病变诊断中的应用价值[J].临床放射学杂志,2001,20(2):85-88. 被引量:37
  • 3顾明,周明.磁共振扩散成像及其临床运用[J].中国医学影像技术,1998,14(7):542-544. 被引量:6
  • 4谢敬霞,韩鸿宾.磁共振扩散成像的生物物理学机制和临床应用价值[J].中华放射学杂志,1999,33(10):653-654. 被引量:12
  • 5刘定西,于群.MR成像技术分册[M].武汉:湖北科学技术出版社,1999.76—103.
  • 6Tha KK, Terae S, Yamamoto T,et al. Early Detection of Global Cerebral Anoxia: Improved Accuracy by High-b-value Diffusion-weighted Imaging with Long EchoTime[J]. AJNR(S0195-6108), 2005,26(6): 1487-1497.
  • 7Pierre B,Thomas P, Maranal A,et al. Water Diffusion Compartmentation at High b Value in Ischemic Human Brain [J]. AJNR(S0195- 6108), 2004,25 (5): 691 - 698.
  • 8Kim HJ, Choi CG, Lee DH,et al. High-b-value Diffusion-weight MR Imaging of Hyperacute Isehemic Stroke at 1. 5T [J]. AJNR(S0195 - 6108), 2005,26 (2) :208-215.
  • 9Meyer JR, Gutierrez A, Mock B, et al. High-b-value Diffusion-Weighted MR Imaging of Suspected Brain Infarction[J].AJNR (S0195 - 6108), 2000, 21 ( 11 ) : 1821-1829.
  • 10Seo HS,Chang KH,Na DG,et al. High b-value Diffusion (b=3000 s/mm2) MR Imaging in cerebral Gliomas at 3T:Visual and Quantitative Comparisons with b=1000 s/ram2[J]. AJNR(S0195-6108),2008,29 (3) :458-463.

二级参考文献15

  • 1Yamashita Y,J Magn Reson Imaging,1998年,8卷,367页
  • 2韩鸿宾,中华放射学杂志,1998年,32卷,364页
  • 3Choi S H,Neurology,2000年,54卷,83页
  • 4Roh J K,Stroke,2000年,31卷,688页
  • 5Chu B C,No To Shinkei,1998年,50卷,787页
  • 6Lansberg MG, Albers GW, Beaulieu C, et al. Comparison of diffusion-weighted MRI and CT in acute stroke [J]. Neurology, 2000, 54: 1557- 1561.
  • 7Nail B, Inanc G, Onder O, et al. The added value of the apparent diffusion coefficient calculation to magnetic resonance imaging in the differentiation and grading of malignant brain tumors [ J ]. J Comput Assist Tomogr, 2004, 28 (6): 735-746.
  • 8Kurihara Y, Yakushiji YK, Tani L, et al. Coil sensitivity encoding in MR imaging: advantages and disadvantages in clinical practice [J]. AIR, 2002, 178: 1087-1091.
  • 9Fiebach JB, Schellinger PD. Stroke magnetic resonance imaging is accurate in hyperacute intracerebral hemorrhage: a multicenter study on the validity of stroke imaging [J]. Stroke, 2004, 35:502 -506.
  • 10Sehellinger PD, Jansen O. A standardized MRI stroke protocol: comparison with CT in hyperacute intracerebral hemorrhage [ J]. Stroke, 1999, 30: 1974-1975.

共引文献83

同被引文献3

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部