摘要
本文介绍了铁屑处理镀铬废水中六价铬的反应动力学影响因素。结果表明在固-液比M/V=1.5g/ml;温度T=20℃;铁屑粒径D=1.0-2.0mm;活化时间Ta=20min的条件下,K值保持稳定,反应进行得最快,出水水质达到国家排放标准。
The article introduced the influcnce of factor on the kinetics in handling the waste water of chrohaum-pioting by the iron- scraps. Under some condition, the results showed whcn control the rate of solid-liquid was1. 5g/ml; thetemperatute was 20℃;iron-scraps size was 1.0 - 2. 0mm;the activation time was 20 min,the K value was steadily. Thereaction speed was fast. The water quatily of out -water reached national emission standard.