摘要
首先介绍了承压水对深基坑工程的影响,其次系统阐述了天津地铁新开路站降压井的设计与施工技术要点,最后从现场监测情况分析了降水设计的合理性,以积累降压井设计施工经验,保证工程施工的顺利进行。
The confined water influences on deep excavation engineering was introduced at first,then the water lowering well design and construction points of Tianjin subway Xinkai road station were illustrated systematically.At last,the dewatering design rationality was analyzed from site monitoring situation,so as to accumulate water lowering well design construction experience and guarantee engineering construction smoothly running.
出处
《山西建筑》
2010年第2期136-137,共2页
Shanxi Architecture
关键词
承压水
降压井
设计
施工
监测
confined water
water lowering well
design
construction
monitoring