期刊文献+

基于微型呼吸传感器的高血压治疗系统 被引量:4

Hypertension therapeutic system based on micro-breathing sensor
在线阅读 下载PDF
导出
摘要 采用压阻式全桥型腹带式微型呼吸传感器检测人体的呼吸信号,研制基于慢呼吸训练的高血压治疗系统,以单片机AT89C51为核心,用全速USB接口芯片PDIUSBD12实现单片机与计算机之间的通信;采用Microsoft Visual C++6.0编写上位机软件,根据生物信息反馈原理设计以呼吸信号为反馈生理量的慢呼吸引导算法,以直观的音乐信号和进度条指示受试者进行呼气和吸气。进行了志愿者实验,结果表明:本系统能够有效地引导受试者进行慢呼吸训练,受试者血压下降较为显著。 A novel hypertension therapeutic system using abdominal-bandage micro-breathing sensor for human respiratory signal detection is developed on the basis of slow-breath training mechanism. The system takes singlechip microcomputer AT89C51 as core processor that communicates with PC via full-speed interface chip PDIUSBD12 and is programmed by Microsoft Visual C + +6.0 according to slow-breath guided algorithm in which the respiratory signal serves as feedback physiological parameter. The inhalation and exhalation of the subject is directed by straightforward music signal. The primary experiment indicates that the system instructs the subject to perform slow-breath training and is responsible for the evident decrease in blood pressure.
出处 《传感器与微系统》 CSCD 北大核心 2009年第12期70-73,共4页 Transducer and Microsystem Technologies
基金 重庆市科技攻关计划资助项目(CSTC2008AA5010)
关键词 微型呼吸传感器 单片机 高血压 慢呼吸 micro-breathing sensor single-chip microcomputer hypertension slow-pace breath
  • 相关文献

参考文献9

  • 1Kikuo Arakawa. Non-pharmacologic measures for lowering blood pressure[ J ]. Cardiovascular Drugs and Therapy, 1989,3 ( 6 ) : 847 -52.
  • 2Non-pharmacological approaches to the control of high blood pressure[ R]. Final report of the Subcommittee on Non-pharmacological Therapy of the 1984 Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure. American Heart Association : Hypertension, 1986:444 -467.
  • 3Brownstein A H, Dembert M L. Treatment of essential hypertension with yoga relaxation therapy in a USAF aviator: A ease report[ J]. Aviat Space Environ Med ,1989,60 ( 7 ) :684 -687.
  • 4Blackwell B. Transcendental meditation in hypertension. Individual response patterns[ J ]. Lancet, 1976,1 ( 7953 ) :223 -226.
  • 5Bernardi L, Gabutti A, Porta C, et al. Slow breathing reduces chemoreflex response to hypoxia and hypercapnia, and increases baroreflex sensitivity[ J ]. J Hypertens,2001 (19) :2221 -2229.
  • 6Bemardi L, Porta C, Spicuzza L, et al. Slow breathing increases arterial baroreflex sensitivity in patients with chronic heart failure[ J ]. Circulation,2002,105 (2) : 143 -145.
  • 7Grossman E, Grossman A, Schein M H, et al. Breathing control lowers blood pressure[J]. J Hum Hypertens,2001,15(4) :263 - 269.
  • 8王朔,李刚.USB接口器件PDIUSBD12的接口应用设计[J].单片机与嵌入式系统应用,2002(4):56-59. 被引量:33
  • 9周立功.PDIUSBD12 USB固件编程与程序开发[M].北京:北京航天工业大学出版社,2003:188-238.

二级参考文献2

  • 1[1]Philips Corp. PDIUSBD12 Users Manual
  • 2[2]Universal Serial Bus Specification, Compaq, Intel, Micrisoft,NEC,Revision 1.1 September 23, 1998

共引文献32

同被引文献40

引证文献4

二级引证文献27