期刊文献+

土遗址墙体含水量与电阻率关系研究 被引量:18

RESEARCH ON RELATIONSHIPS BETWEEN WATER CONTENT AND RESISTIVITY OF EARTHEN RUIN WALLS
在线阅读 下载PDF
导出
摘要 多孔介质电阻率的影响因素很多,对于特定结构的土遗址墙体,电阻率的变化取决于水分和温度的变化。对交河故城土遗址墙体夯土电阻率模型分析,结合改进的Archie模型,建立特定结构墙体电阻率模型,通过室内电阻率与含水量的关系试验,确定模型公式中的结构参数和土性参数。根据试验建立的墙体电阻率反演含水量关系式,采用高密度电阻率层析法,对交河土遗址现场试验墙体进行尝试性测试。测试结果论证了该模型公式的实用性,为土遗址文物本体水分运移监测中的实际应用奠定基础。 Porous media resistivity is affected by a number of factors.In the specific structure of the soil wall sites,changes in resistivity depend on the moisture and temperature changes.By the resistivity model analysis of rammed earth wall in Ruins of Jiaohe,combining with the improved Archie model,a resistivity model for the wall in a specific structure is established by the tests to find out the relation between water content and resistivity,and to determine the structural parameters and soil parameters in the model formula.According to the established formula by the moisture inversion with the resistivity,using high-density resistivity chromatography,the field wall in Ruins of Jiaohe is tested.The results demonstrate the practicality of the model formula in relics sites,which lays foundation for practical application of monitoring water translocation in relics sites.
出处 《岩石力学与工程学报》 EI CAS CSCD 北大核心 2009年第A02期4054-4058,共5页 Chinese Journal of Rock Mechanics and Engineering
基金 国家"十一五"科技支撑项目(2006BAK30B02)
关键词 土力学 交河故城 土遗址 水分监测 电阻率模型 水分运移 高密度电阻率法 soil mechanics Ruins of Jiaohe earthen ruin wall moisture monitoring resistivity model water translocation high-density resistivity method
  • 相关文献

参考文献17

  • 1孙满利,王旭东,李最雄,谌文武.交河故城的裂隙特征研究[J].岩土工程学报,2007,29(4):612-617. 被引量:23
  • 2陈洪松,邵明安.中子仪的标定及其在坡地土壤水分测量中的应用[J].干旱地区农业研究,2003,21(2):68-71. 被引量:26
  • 3伍永秋,刘宝元,Erik van den Elsen,张清春,张岩.黄土高原土壤水分的自动监测——TDR系统及其应用[J].水土保持学报,2001,15(2):108-111. 被引量:27
  • 4FERRE P A, REDMAN J D, RUDOLPH D L, et al. The dependence of the electrical conductivity measured by time domain reflectometry on the water content of a sand[J]. Water Resources Research, 1998, 34(5): 1 207 - 1 213.
  • 5ZHU Jiao-Jun,KANG Hong-Zhang,Y. GONDA.Application of Wenner Configuration to Estimate Soil Water Content in Pine Plantations on Sandy Land[J].Pedosphere,2007,17(6):801-812. 被引量:9
  • 6SHEETS K R, HENDRICKX J M H. Non-invasive soil water content measurements using electromagnetic induction[J]. Water Resources Research, 1995, 31(10): 2401-2409.
  • 7ARCHIE G E. The electric resistivity log as an aid in determining some reservoir characteristics[J]. Transactions of the American Institute of Mining and Metallurgical Engineers, 1942, 146:54 - 61.
  • 8KELLER G V, FRISCHKNECHT F C. Electrical methods in geophysical prospecting[M]. New York: Pergamon Press, 1966.
  • 9WAXMAN M H, SMITS L J M. Electrical conductivity in oil-bearing shaly sand[J]. Society of Petroleum Engineers Journal, 1968, 8:107 - 122.
  • 10HALVORSON A D, RHOADES J D. Field mapping soil conductivity to delineate dryland saline seeps with four-electrode technique[J]. Soil Science Society of American Journal, 1976, 40: 571 - 574.

二级参考文献104

共引文献453

同被引文献204

引证文献18

二级引证文献195

相关作者