期刊文献+

A Multifunctional HTDMA System with a Robust Temperature Control 被引量:3

A Multifunctional HTDMA System with a Robust Temperature Control
在线阅读 下载PDF
导出
摘要 The hygroscopicity of atmospheric aerosols significantly influences their size distribution, cloud condensation nuclei ability, atmospheric residence time, and climate forcing. In order to investigate the hygroscopic behavior of aerosol particles and serious haze in China, a Hygroscopic Tandem Differential Mobility Analyzers (HTDMA) system was designed and constructed at Fudan University. It can function as a scanning mobility particle sizing system to measure particle size distribution in the range of 20-1000 nm in diameter, as well as a hygroscopicity analyzer for aerosol particles with diameters between 20-400 nm in the range of 20%-90% RH (relative humidity). It can also measure the effect of uptake of inorganic acids or semiVOCs on the hygroscopic behavior of aerosols, such as typical inorganic salts in atmospheric dust or their mixtures. The performance tests show that the system measured particle size of the standard polystyrene latex spheres (PSLs) is 197 nm, which is in excellent agreement with the certified diameter D=199±6 nm, as well as a standard deviation of the repeated runs SD=8.9×10^-4. In addition, the measured hygroscopic growth factors of the model compounds, (NH4)2SO4 and NaNO3, agree with the Kohler theoretical curves. The results indicate that the HTDMA system is an excellent and powerful tool for studying the hygroscopic behavior of submicron aerosols and meets the demand required for laboratory research and fieldwork on atmospheric aerosols in China. The hygroscopicity of atmospheric aerosols significantly influences their size distribution, cloud condensation nuclei ability, atmospheric residence time, and climate forcing. In order to investigate the hygroscopic behavior of aerosol particles and serious haze in China, a Hygroscopic Tandem Differential Mobility Analyzers (HTDMA) system was designed and constructed at Fudan University. It can function as a scanning mobility particle sizing system to measure particle size distribution in the range of 20-1000 nm in diameter, as well as a hygroscopicity analyzer for aerosol particles with diameters between 20-400 nm in the range of 20%-90% RH (relative humidity). It can also measure the effect of uptake of inorganic acids or semiVOCs on the hygroscopic behavior of aerosols, such as typical inorganic salts in atmospheric dust or their mixtures. The performance tests show that the system measured particle size of the standard polystyrene latex spheres (PSLs) is 197 nm, which is in excellent agreement with the certified diameter D=199±6 nm, as well as a standard deviation of the repeated runs SD=8.9×10^-4. In addition, the measured hygroscopic growth factors of the model compounds, (NH4)2SO4 and NaNO3, agree with the Kohler theoretical curves. The results indicate that the HTDMA system is an excellent and powerful tool for studying the hygroscopic behavior of submicron aerosols and meets the demand required for laboratory research and fieldwork on atmospheric aerosols in China.
出处 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2009年第6期1235-1240,共6页 大气科学进展(英文版)
基金 support from the National Natural Science Foundation of China(Grant Nos.40533017,40775080,40728006) the key project from the Ministry of Education of China(Grant No.108050) the Research Fund for the Doctoral Program of Higher Education(Grant No.20070246024)
关键词 HTDMA hygroscopic behavior atmospheric aerosols set up EVALUATION HTDMA, hygroscopic behavior, atmospheric aerosols, set up, evaluation
  • 相关文献

参考文献25

  • 1Berg,O.H.,E.Swietlicki,and R.Krejci,1998:Hygroscopic growth of aerosol particles in the marine boundary layer over the Pacific and Southern Oceans during the First Aerosol Characterization Experiment (ACE 1).J.Geophys.Res.,103,16535-16545.
  • 2Broday,D.M.,and P.G.Georgopoulos,2001:Growth and deposition of hygroscopic particulate matter in the human lungs.Aerosol Science and Technology,34,144-159.
  • 3Chan,H.K.,S.Eberl,E.Daviskas,C.Constable,and Ⅰ.Young,2002:Changes in lung deposition of aerosols due to hygroscopic growth:A fast SPECT study.Journal of Aerosol Medicine-Deposition Clearance And Effects in the Lung,15,307-311.
  • 4Cocker,D.R.,N.E.Whitlock,R..C.Flagan,and J.H.Seinfeld,2001:Hygroscopic properties of Pasadena,California aerosol.Aerosol Science and Technology,35,637-647.
  • 5Collins,D.R,R.C.Flagan,and J.H.Seinfeld,2002:Improved inversion of scanning DMA data.Aerosol Science and Technology,36,1-9.
  • 6Day,D.E.,J.L.Hand,C.M.Carrico,G.Engling,and W.C.Maim,2006:Humidification factors from laboratory studies of fresh smoke from biomass fuels.J.Geophys.Res.,111,D22202,doi:10.1029/2006JD007221.
  • 7Duplissy,J.,and Coauthors,2008:Intercomparison study of six HTDMAs:Results and general recommendations for HTDMA operation.Atmospheric Measurement Techniques Discussions,1,127-168.
  • 8Ferron,G.A.,W.G.Kreyling,and B.Haider,1988:Inhalation of salt aerosol particles-Ⅱ.Growth and deposition in the human respiratory tract.Journal of Aerosol Science,19,611-631.
  • 9Matsumura,T.,and M.Hayashi,2007:Hygroscopic growth of an (NH4)2SO4 aqueous solution droplet measured using an environmental scanning electron microscope(ESEM).Aerosol Science and Technology,41,770-774.
  • 10McMurry,P.H.,and M.R.Stolzenburg,1989:On the sensitivity of particle size to relative humidity for Los Angeles aerosols.Atmos.Environ.,23,497-507.

同被引文献80

引证文献3

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部