摘要 用蒙特卡罗方法研究了能量为(30~110)keV的单能X射线在铁中的吸收及散射特性,给出了散射光子的角分布及背向散射光子的能谱分布。结果表明,在入射X光子能量较低的情况下,背向散射光子主要是铁的特征X射线光子。随着入射能量的升高,背向散射光子中高能量的散射光子数增多,特征X光子数目迅速减少。 Absorption and scattering properties of monoenergetic X rays of 30 keV-110 keV in iron have been studied with Monte Carlo method. The angular distributions of scattered photons and the spectra of backscattered radiation are presented. The results show that the backscattered radiation is primarily the characteristic X radiation of iron for the incident X rays of low energy, and that with the energy of incident X rays increasing, the backscattered radiation of high energy increases and the characteristic X radiation decreases rapidly.
出处 《光学学报》 EI CAS CSCD 北大核心 1998年第9期1197-1202,共6页 Acta Optica Sinica
基金 国家自然科学基金
关键词 康普顿散射 瑞利散射 X射线 影像增强器 Compton scatter, Rayleigh scatter, backscatter, Monte Carlo method.
  • 相关文献

参考文献5

  • 1Cheng C W,Med Phys,1995年,22卷,8期,1235页
  • 2高明坤,实用概率统计学,1988年,291页
  • 3Chen H P,Med Phys,1985年,12卷,2期,152页
  • 4谢忠信,X射线光谱分析,1982年,45页
  • 5裴鹿成,蒙特卡罗方法及其在粒子输运问题中的应用,1980年,64页

同被引文献46

  • 1Rowlands J A Nalcioglu O.X射线影像增强荧光透视中杂散光的PSF特征[J].医学物理,1984,11(2):172-179.
  • 2Seibert J A Nalcioglu O.用数学去卷积技术排除影像增强器中的杂散光[J].医学物理,1985,12(3):281-288.
  • 3Luhta R Rowlands J A.X射线影像增强器中的杂散光[J].医学物理,1990,17(5):913-921.
  • 4Harrison R M.数学X射线成像-探测器设计评述[J].物理研究中的核仪器和方法,1991,310(1):24-34.
  • 5Boone J M Seibert J A.影像增强器-TV-数字化器链中的不完整性的分析和修正[J].医学物理,1991,18(2):236-242.
  • 6McRobbie D W Nieto-Camero J J.用视频信号分析方法测量影像增强器的调制传递函数[J].医学物理,1994,21(2):257-264.
  • 7Thirlwall J T.医学X射线影像增强器的探测量子效率[J].科学仪器评论,1998,69(11):3953-3957.
  • 8曾宇.[D].北京:清华大学工程物理系,1995.
  • 9李金升.[D].北京:清华大学工程物理系,1997.
  • 10王延平.信号复原与重建.东南大学出版社,1992