螺旋浆技术在颅脑磁共振成像中的临床应用价值

The Clinical Value of Properller MRI for Brain Imaging
暂未订购
导出
摘要 目的探讨应用螺旋浆技术改善颅脑磁共振成像运动伪影的效果。方法选取60例临床受检者和10例不同状态的健康志愿者,用1.5T高场双梯度磁共振扫描仪,对每一层面分别行PROP-T2WI和FSE-T2WI序列轴位扫描。由3位高年资的影像科医师对图像质量进行评价,分析两种序列图像的运动伪影和优质片率状况。结果PROP-T2WI扫描序列比常规FSE-T2WI扫描序列所获得的图像运动伪影减少,优质图像的百分率明显提高,经检验,差异均有统计学意义(P<0.001)。对颅内病变的显示能力,PROP-T2WI优于FSE-T2WI,PROP-T2WI能清晰显示小病灶。结论PROP-T2WI为显著头动患者进行磁共振检查提供一种可能,避免对躁动患者实施药物镇静或进行全身麻醉,具有较高临床实用价值。 Objective To evaluate effects of PROPELLER MRI on brain imaging.Methods We performed axial PROP-T2WI and conventional FSE-T2WI in sixty clinical subjects and ten normal volunteers with 1.5-Tesla GE Signa HD scanner.Imaging were examined by three radiologists for motion artifact and for overall imaging quality.By usingχ^2 test,we analyzed motion artifact and rate of high quality film of the two sequence imagings.Results Motion artifact was less co mmonly seen on PROP-T2WI than conventional FSE-T2WI(P〈0.001).PROP-T2WI was preferred over conventional in all subjects(P〈0.01).Intracranial pathology was better demonstrated with PROP-T2WI.Conclusion PROP-T2WIoffers a novel means of reducing motion artifact and improving imaging quality for head motion.It offer important benefits for brain imaging in all subjects,regardless of motion.
出处 《医学综述》 2009年第21期3339-3341,共3页 Medical Recapitulate
关键词 螺旋浆技术 磁共振成像 颅脑 图像质量 运动伪影 PROPELLER Magnetic resonance imaging Brain Image quality Motion artifact
  • 相关文献

参考文献5

二级参考文献35

  • 1侯正松,江贵平,王华峰,陈武凡.MR图像刚性平移运动伪影的自动逆向迭代修正[J].中国生物医学工程学报,2004,23(4):353-358. 被引量:9
  • 2秦文,于春水,李坤成.螺旋桨(PROPELLER)技术的原理及应用[J].医学影像学杂志,2005,15(10):912-915. 被引量:24
  • 3戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 4史进忠,尹培尧.核磁共振MRCP成像原理及成像技术[J].医疗设备信息,2007,22(3):100-101. 被引量:18
  • 5Nishimura DG,Irarrazabal P,Meyer CH.A velocity k-space analysis of flow effects in echo-planar and spiral imaging.Magn Reson Med,1995,33:549-556.
  • 6Glover GH,Pauly JM.Projection reconstruction techniques for reduction of motion effects in MRI.Magn Reson Med,1992,28:275-289.
  • 7Meyer CH,Hu BS,Nishimura DG,et al.Fast spiral coronary artery imaging.Magn Reson Med,1992,28:202-213.
  • 8Ehman R,Felmlee J.Adaptive technique for high-definition MR imaging of moving structures.Radiology,1989,173:255-263.
  • 9Ordidge RJ,Helpern JA,Qing ZX,et al.Correction of motional artifacts in diffusion-weighted MR images using navigator echoes.Magn Reson Imaging,1994,12:455-460.
  • 10Sachs T,Meyer CH,Irarrazabal P,et al.The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.Magn Reson Med,1995,34:412-422.

共引文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部