期刊文献+

Using a biological aerated filter to treat mixed water-borne volatile organic compounds and assessing its emissions 被引量:3

Using a biological aerated filter to treat mixed water-borne volatile organic compounds and assessing its emissions
在线阅读 下载PDF
导出
摘要 A biological aerated filter (BAF) was evaluated as a fixed-biofilm process to remove water-borne volatile organic compounds (VOCs) from a multiple layer ceramic capacitor (MLCC) manufacturing plant in southern Taiwan. The components of VOC were identified to be toluene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, bromodichloromethane and isopropanol (IPA). The full-scale BAF was constructed of two separate reactors in series, respectively, using 10- and 15-cm diameter polypropylene balls as the packing materials and a successful preliminary bench-scale experiment was performed to feasibility. Experimental results show that the BAF removed over 90% chemical oxygen demand (COD) from the influent with (1188 ± 605) mg/L of COD. A total organic loading of 2.76 kg biochemical oxygen demand (BOD)/(m3 packing·d) was determined for the packed bed, in which the flow pattern approached that of a mixed flow. A limited VOC concentration of (0.97 ± 0.29) ppmv (as methane) was emitted from the BAF system. Moreover, the emission rate of VOC was calculated using the proposed formula, based on an air-water mass equilibrium relationship, and compared to the simulated results obtained using the Water 9 model. Both estimation approaches of calculation and model simulation revealed that 0.1% IPA (0.0031-0.0037 kg/d) were aerated into a gaseous phase, and 30% to 40% (0.006-0.008 kg/d) of the toluene were aerated. A biological aerated filter (BAF) was evaluated as a fixed-biofilm process to remove water-borne volatile organic compounds (VOCs) from a multiple layer ceramic capacitor (MLCC) manufacturing plant in southern Taiwan. The components of VOC were identified to be toluene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, bromodichloromethane and isopropanol (IPA). The full-scale BAF was constructed of two separate reactors in series, respectively, using 10- and 15-cm diameter polypropylene balls as the packing materials and a successful preliminary bench-scale experiment was performed to feasibility. Experimental results show that the BAF removed over 90% chemical oxygen demand (COD) from the influent with (1188 ± 605) mg/L of COD. A total organic loading of 2.76 kg biochemical oxygen demand (BOD)/(m3 packing·d) was determined for the packed bed, in which the flow pattern approached that of a mixed flow. A limited VOC concentration of (0.97 ± 0.29) ppmv (as methane) was emitted from the BAF system. Moreover, the emission rate of VOC was calculated using the proposed formula, based on an air-water mass equilibrium relationship, and compared to the simulated results obtained using the Water 9 model. Both estimation approaches of calculation and model simulation revealed that 0.1% IPA (0.0031-0.0037 kg/d) were aerated into a gaseous phase, and 30% to 40% (0.006-0.008 kg/d) of the toluene were aerated.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第11期1497-1502,共6页 环境科学学报(英文版)
关键词 volatile organic compounds biological aerated filter total organic loading emission volatile organic compounds biological aerated filter total organic loading emission
  • 相关文献

参考文献25

  • 1APHA (American Public Health Association), 1992. Standard Methods for the Examination of Water and Wastewater (14th ed.) Washington DC: American Water Work Association & Water Pollution Control Federation.
  • 2Cheng W H, Chou M S, 2003. VOC emission characteristics of petrochemical wastewater treatment facilities in southern Talwan. Journal of Environmental Science and Health, Part A, 38: 2521-2535.
  • 3Cheng W H, Chou M S, Perng C H, Chu F S, 2004. Determining the equilibrium partitioning coefficients of volatile organic compounds at an air-water interface. Chemosphere, 54: 935-942.
  • 4Cheng W H, Chu F S, Liou J J, 2003. Air-water interface equilibrium partitioning coefficients of aromatic hydrocarbons. Atmospheric Environment, 37:4807-4815.
  • 5Contacted Aeration Treats Industrial Wastewater, 1991. Handbook of Industrial Pollution Prevention. Vol. No. 12. Taipei, Talwan: China Technology Consultant Incorporation.
  • 6Corseuil H X, Hunt C S, SantosR C F D, Alvarez P J J, 1998. The influence of the gasoline oxygenate ethanol on aerobic and anaerobic BTX biodegradation. Water Research, 32: 2065- 2072.
  • 7Friday D D, Portier R J, 1991. Development of an immobilized microbe bioreactor for VOC application. Environmental Progress, 10: 30-39.
  • 8Goeddertz J G, Weber A S, Ying W C, 1990. Startup and operation of a biological activated carbon (AnBAC) process for treatment of a high strength multicomponent inhibitory wastewater. Environmental Progress, 9:110-117.
  • 9Gupta A S, Thodos G, 1962. Mass and heat transfer through fixed and fluidized beds. Chemical Engineering Progress, 58: 58- 62.
  • 10Hill G A, Tomusiak M E, Quail B, Van Cleave K M, 1991. Bioreactor design effects on biodegradation capabilities of VOCs in wastewater. Environmental Progress, 10: 147-153.

同被引文献27

  • 1王萍,李国昌.曝气生物滤池陶粒滤料制备及其性能[J].非金属矿,2006,29(5):53-55. 被引量:9
  • 2DING Yong-wei,WANG Lin,WANG Bao-zhen,WANG Zheng.Removal of nitrogen and phosphorus in a combined A^2/O-BAF system with a short aerobic SRT[J].Journal of Environmental Sciences,2006,18(6):1082-1087. 被引量:16
  • 3SHEN Ying-jie,WU Guang-xia,FAN Yao-bo,ZHONG Hui,WU Lin-lin,ZHANG Shao-lai,ZHAO Xian-hong,ZHANG Wei-jun.Performances of biological aerated filter employing hollow fiber membrane segments of surface-improved poly(sulfone) as biofilm carriers[J].Journal of Environmental Sciences,2007,19(7):811-817. 被引量:9
  • 4HONG-DUCK RYU, DAEKEUN KIM, HEUN-EUN LIM, et al. Nitrogen removal from low carbon-to- nitrogen wastewater in four-stage biological aerated filter system[J]. Process Biochemistry, 2008,43 (7): 729-735.
  • 5FANG LIU, CHAO-CHENG ZHAO, DONG-FENG ZHAO, et al. Tertiary treatment of textile wastewater with combined media biological aerated filter (CMBAF) at different hydraulic loadings and dissolved oxygen concentrations [J].Journal of Hazardous Materials,2008,160(1):161- 167.
  • 6PUJOL R, LEMMEL H, GOUSAILLES M. A keypoint of nitrification in an upflow biofihration reactor[J].Wat SciTech, 1998,38(3)43-49.
  • 7FRANCISCO OSORIO, ERNESTO HONTORIA. Wastewater treatment with a double-layer submerged biological aerated filter, using waste materials as biofilm support [J].Journal of Environmental Management, 2002, 65(1) :79-84.
  • 8YAQIN ZHAO, QINYAN YUE, RENBO LI, et al. Research on sludge-fly ash ceramic particles (SFCP) for synthetic and municipal wastewater treatment in biological aerated filter ( BAF ) [J].Bioresource Technology, 2009,100(21 ) : 4955-4962.
  • 9WON- SEOK CHANG, HUNG-THUAN TRAN, DOO-HYUN PARK, et al. Ammonium nitrogen removal characteristics of zeolite media in a Biological Aerated Filter (BAF) for the treatment of textile wastewater[J].Journal of Industrial and Engineering Chemistry, 2009,15(4) :524-528.
  • 10苏德林,王建龙,刘凯文,周定.Kinetic Performance of Oil-field Produced Water Treatment by Biological Aerated Filter[J].Chinese Journal of Chemical Engineering,2007,15(4):591-594. 被引量:24

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部