摘要 人工心脏为衰竭的心脏提供有效的机械辅助,其中人工心脏血泵控制和评估的实现需要血泵检测。本文综述了人工心脏血泵检测的参数和方法,其中血泵的主要测量参数包括流量、压力等流体机械参数和血栓、溶血等反映血液破坏情况指标。另外,文章介绍了血泵参数的直接测量法及为避免与血液接触引起血液兼容性问题的间接测量方法。最后,本文探讨了人工心脏血泵检测的主要挑战及可能的发展方向。 Artificial heart is used to treat severe heart failure as an effective mechanical assist, in which control and evaluation are based on the measurement of the blood pump. This paper reviews the questions of what must be measured and how they can be measured regarding to the blood pump, discussing the main mechanical-fluid parameters such as flow rate, pressure, and some blood damage indicators such as thrombus and plasma free hemoglobin. Also in a number of these cases, the indirect measurements are introduced to avoid the limits of blood-compatibility. This review concludes with the main challenges and possible trends for the further development of the blood pump measurement.
作者 杨明
出处 《电子测量与仪器学报》 CSCD 2009年第10期1-7,共7页 Journal of Electronic Measurement and Instrumentation
基金 国家自然科学基金(编号:30670524)资助项目 上海市浦江人才计划(编号:07pj14054)资助项目
关键词 人工心脏 血泵 检测 artificial heart blood pump measurement
  • 相关文献

参考文献3

二级参考文献33

  • 1李孝安.神经网络与神经计算机导论[M].西安:西北工业大学出版社,1995,10..
  • 2Masuzawa, Toru. Cardiac output estimation model with a neural network toward total artificial heart control. Proc. Annual Conf Eng Med Biol v 15 pt 2 1993 proceedings of the 15th Annual Intemational Conference of IEEE Engineering in Medicine and Biology Society, IEEE, USA, 1993. 932~933.
  • 3Yoshinari Wakisaka, Yasuki Okuzono, Yoshiyuki Taenaka, et al. Noninvasive Pump Flow Estimation of a Centrifugal Blood Pump. Artificial Organs, 1997,21 (7) :651~654.
  • 4查森编,叶片泵原理及水力设计,镇江,江苏大学,1992.20-74.
  • 5Kosaka R,Sankai Y,Jikuya T,et al.Resonant Frequency Control for Artificial Heart Using Online Parameter Identification.Artificial Organs,2004,28 (10):921-926
  • 6Antaki JF,Simaan MA.Hirarchical control of heart assist devices.IEEE Robotics& Automation magazine,2003,3:54 -64
  • 7Iojima T,Inamoto T,Ngawa M,et al.Control of centrifugal blood pump based on the motor current.Artificial Organs,1997,26(2):396 -399
  • 8Choi S,Antaki JF,Boston JR,et al.A Sensorless Approach to Control of A Turbodynamic Left Ventricular Assist System.IEEE Trans CST,2001,9(3):473 -482
  • 9Yoshinari W,Yasuki O,Yoshiyuki T,et al.Noninvasive pump flow estimation of a centrifugal blood pump.Artificial Organs,1997,21(7):651 -654
  • 10Maslen EH,Bearnson GB,Allaire PE.Feedback Control Applications in Artificial Hearts.

共引文献10

同被引文献61

引证文献6

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部