摘要
根据线路的线损率和电压损失的定义和计算公式,推导和分析了两者之间的关系,提出在工程设计阶段通过计算线路电压损失估算预期的线损率,并对企业常用的供电线路电压损失的控制值提出建议。
According to definitions as well as calculation formulae of line loss rate and voltage loss of power lines, the paper derivation and analyzed their interrelation, estimated expected line loss rate by means of calculating line voltage loss during engineering design phase, and put forward suggestions on control values of voltage loss of power supply lines commonly applied in enterprises.
出处
《中国有色冶金》
北大核心
2009年第5期33-35,共3页
China Nonferrous Metallurgy
关键词
线损率
电压损失
工程应用
loss rate
voltage loss
engineering application