摘要
目的:建立全血中铅的直接快速石墨炉原子吸收光谱分析方法。方法:石墨炉原子吸收光谱仪经优化条件后以硝酸和TritonX-100作为样品稀释液,用磷酸二氢铵作化学改进剂,横向加热塞曼扣除背景,石墨炉原子吸收光谱法直接自动进样测定。结果:分析标准牛血GBW(E)090033、090035中铅的含量,测定结果与标准值相吻合,11次空白测量检出限为1.29μg/L,特征浓度为0.33μg/L/1%A,样品最低检出质量浓度为2.13μg/L,线性范围为0.00~50.0μg/L,相对标准偏差(RSD)为0.043%~0.67%。样品连续6 d测定的相对标准偏差(RSD)为1.23%~6.54%,加标回收率为98.6%~104.6%。结论:本法灵敏度高,重复性好,结果准确可靠,基底干扰效应小,自动化程度高,操作简便。
Objective:To establish the method of analysising the lead in the whole blood by graphite furnace atomic absorption spectrometry(AAS) directly and rapidly.Methods:The atomic absorption spectrometer was optimized,Nitric acid and TritonX-100 dealed with the sample dilution,Ammonium dihydrogen phosphate(ADP) acted as the basal body improver,then transversal heated the Zee-man and deduct the background,the sample was automatic sampling and the lead was detected by AAS.Results:Analying the contents of lead in standard ox blood GBW(E) 090033,090035 coincided with the certified value.Sample introduction 1ul,the lowest detected mass concentration was 2.13 μg/L,the linear range was 0.00~50.0 μg/L.the relative standard deviation(RSD) was 0.043%~0.67%,the sample was dected continuously in six days and the relative standard deviation was 1.23%~6.54%,the recovery rate of adding standard ox blood was 98.6%~104.6%.Conclusion:This methed has higher sensitivity,better reproducibility and the result is exact.The interference of basal body is fewer and the operation is convenient.
出处
《中国卫生检验杂志》
CAS
2009年第11期2542-2544,共3页
Chinese Journal of Health Laboratory Technology
关键词
石墨炉原子吸收光谱法
全血
铅
Graphite furnace atomic absorption spectrometry
GFAAS
Whole blood
Lead