在已有研究成果的基础上,进一步探讨了现浇钢筋混凝土楼板裂缝产生的原因,并从设计、材料、温度、施工方面提出相应的防治措施和处理方法,从而减少混凝土裂缝的出现。
Based on existing research results,the paper further explores the reasons for cracks on cast-in-place reinforced concrete floor and points out relative preventive measures and treatment methods from the design,the materials,the temperature and the construction,so as to reduce the cracks in concrete.