摘要
本文通过安装于海上某油田海管入口端的旁路式腐蚀检测系统,分别采用平均极化电阻值(Rp),腐蚀挂片和XRD垢样分析方法,并对试验管段腐蚀状况进行了分析,做出相应的评价。
In this paper, corrosion situation of detected pipeline section is analyzed and relevant evaluation is made through by- pass corrosion monitoring system installed at the entrance of marine pipeline of certain oilfield. Average polarization resistance(Rp) corrosion, hanging slice and XRD scale sample analysis method are adopted.
出处
《全面腐蚀控制》
2009年第10期36-39,共4页
Total Corrosion Control