摘要 对无手术和有连续手术或手术历时2h~3h的3个手术间进行空气细菌含量监测。结果:无手术的手术间于消毒后6h内均无菌落生长,而12h、22h平均菌落数为132cfu/m3。有手术的手术间于消毒后4h内无菌落生长,6h后空气细菌含量严重超标,在采取相应的措施后,达到了标准。提示临床应重视手术时间长或连续手术的手术间空气消毒,严格控制人员流动。 The air bacterium contamination of 3 operating rooms:without operation,with continuous operation and with 2h~3h operation was monitored.Results showed that in the operating room without operation the colony not appeared during 6h after disinfection,whereas mean colony content at 12 h and 22 h was 132 /m 3;in the rooms with operation the colony not appeared during 4h,but after 6 h the bacterium content was seriously exceeded standard and following adopting the relevant measures it arrived at the standard.Results suggest that an attention be paid to the disinfection of operating rooms with long or continuous operation.
出处 《山西护理杂志》 1998年第5期204-205,共2页
关键词 手术间 空气 细菌监测 细菌污染 Operating rooms Air Bacterium monitoring