摘要 建立预警系统是保障城市供水卫生的重要途径,而预警监测站的部署(选择合理的监测站个数和布局)又是建立供水预警系统所要解决的首要问题。根据平均预警时间最短原则构造优化目标函数,利用0-1整数规划对指定数量的监测站进行优化选址;对选址准则函数进行了理论分析和实验研究,提出了合理确定监测站数量的方法。通过实验验证了该方法的有效性,该方法可用以实现预警监测站的自动配置,达到预警系统安全性和经济性的较好平衡。 Establishing monitoring systems is an important sanitation way to guarantee urban water supply security and disposition of the monitoring station. In other words, selecting a reasonable number and layout of stations should be much concerned. In this paper, the optimal layout of a given number of stations is conducted with 0 - 1 integer programming method and principle of minimum average of warning time. And the optimal number of stations can be determined in view of the real situation. Experimental results indicate that this approach is capable of automatic disposition for monitoring stations.
作者 刘征 殷蔚明
出处 《工程勘察》 CSCD 北大核心 2009年第11期67-69,80,共4页 Geotechnical Investigation & Surveying
关键词 供水管网 水污染 预警监测站 规划 water supply system contamination monitoring station layout
  • 相关文献

参考文献6

  • 1Lee B H, Deininger R A. Optimal locations of monitoring stations in water distribution system [J]. J Environ Eng, 1992, 118 ( 1 ) : 4 -16.
  • 2KumarA, Kansal M L, Arora G. Identification of monitoring stations in water distribution system [J]. J Environ Eng, 1997, 123 (8) : 746 - 752.
  • 3AvnerKessler, AviOstfeld, Gideon Sinia. Detecing accidental contaminations inmunicipal water networks [ J ]. JWaterResour Plan Manage, 1998, 124 (4): 192 - 198.
  • 4KumarArun, KansalM L, Arora Geeta. Detecting accidental contaminations in municipal water networks: discussion [J]. J Water Resour Plan Manage, 1999, 125 (5) : 308 - 310.
  • 5JonathanW Berry, Lisa Fleischer, W iniam E Hart, et al. Sensor placement inmunicipal waternetworks [ J ]. J Water Resour Plan Manage, 2005, 131 (3): 237 - 243.
  • 6方海恩,吕谋.供水系统预警监测站的优化布置[J].中国给水排水,2007,23(9):44-47. 被引量:3

二级参考文献7

  • 1许恕,崔双发,孙晓怡,贺斌,陈娟,程锦,李树滢,史玉强.辽宁大伙房水库水质安全预警系统[J].辽宁城乡环境科技,2004,24(4):49-50. 被引量:3
  • 2Avi Ostfeld, Elad Salomons. Optimal layout of early warning detection stations for water distribution system security[J]. J Water Resour Plan Manage,2004,130(5):377 -385.
  • 3Lee B H, Deininger R A. Optimal locations of monitoring stations in water distribution system [ J ]. J Environ Eng,1992,118(1) :4- 16.
  • 4Kumar A, Kansal M L, Arora G. Identification of monitoring stations in water distribution system [ J ]. J Environ Eng, 1997,123 (8) :746 - 752.
  • 5Avner Kessler, Avi Ostfeld, Gideon Sinia. Detecing accidental contaminations in municipal water networks [ J ]. J Water Resour Plan Manage, 1998,124 (4) : 192 - 198.
  • 6Kumar Arun, Kansal M L, Arora Geeta. Detecting accidental contaminations in municipal water networks: dis-cussion [ J ]. J Water Resour Plan Manage, 1999, 125(5) :308 -310.
  • 7Jonathan W Berry, Lisa Fleischer, William E Hart, et al.Sensor placement in municipal water networks [ J ]. J Water Resour Plan Manage ,2005,131 ( 3 ) :237 - 243.

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部