期刊文献+

工业锅炉水总碱度测量法的不确定度评定 被引量:7

Evaluation of the measurement uncertainty of the total alkalinity of water quality in industrial boilers
在线阅读 下载PDF
导出
摘要 对容量法测定工业锅炉水总碱度进行不确定度评定。充分考虑测量重复性、标准溶液的配制、滴定等过程对测量的影响,计算水中总碱度的测量相对合成标准不确定度为3.8×10-3。 The measurement uncertainty of the total alkalinity of water quality in industrial boilers has been evaluated by volumetric method. The effect of the influential factors, such as repetitiveness, preparation of standard solution, titration, etc on the measurement is considered sufficiently. The uncertainty of the relative synthetic standard of the measurement of total alkalinity in water is calculated as 3.8×10^-3.
出处 《工业水处理》 CAS CSCD 北大核心 2009年第10期60-62,共3页 Industrial Water Treatment
关键词 总碱度 测量不确定度 锅炉水 total alkalinity measurement uncertainty boiler water
  • 相关文献

参考文献6

二级参考文献4

  • 1梁景波,袁东晖,黄锦燕,王宝书.水中总硬度测量不确定度的评定[J].中国环境监测,2006,22(3):35-39. 被引量:8
  • 2JJF1059-1999.测量不确定度的评定与表示[S].[S].,..
  • 3GB7477-87.水质总硬度的测定EDTA滴定法[S].
  • 4ISO/IEC17025.1999.检测和校准实验室能力的通用要求[S].

共引文献70

同被引文献70

引证文献7

二级引证文献11