期刊文献+

现代炼钢电弧炉铜-钢复合导电横臂及其阻抗的工程计算 被引量:2

The Engineering Calculation of the Impedance of Copper-steel Compound Conductive Arm for Electric Are Furnace
在线阅读 下载PDF
导出
摘要 炼钢电弧炉短网采用铜-钢复合导电横臂,增加了炉子的可靠性,具有结构简单、强度高、阻抗低,以及重量轻、反应灵敏等特点。根据电流在铜-钢复合导电横臂的分布情况,对其导电截面进行近似简化,得出电抗近似解析计算公式,给出导电横臂阻抗的工程计算方法,为炼钢电弧炉短网优化及改进设计提供了依据。 The application of copper-steel compound conductive arm in electric arc furnace short net improves the reliability of the furnace, which has the advantages of simple structure, high intensity, low impedance, light weight as well as sensitive reaction, This paper proposes an approximate formulation for analyzing electric impedance based on the approximation of its conductive section according to the current distribution in copper-steel compound conductive arm. A method of engineering calculation is also proposed, which provides a good basis for the optimization and design improvement of electric arc furnace short net.
出处 《工业加热》 CAS 2009年第5期16-19,共4页 Industrial Heating
关键词 电弧炉 短网 铜-钢复合导电横臂 阻抗 三相平衡 electric arc furnace short net copper-steel compound conductive arm impedance three-phase balance
  • 相关文献

参考文献6

  • 1阎立懿,肖玉光,李延智,刘一心,胡显坤.现代炼钢电弧炉短网技术[J].工业加热,2006,35(3):17-20. 被引量:6
  • 2邓廷佐.电弧炉短网的计算.工业加热,1974,(3):16-23.
  • 3花皑.三相电弧炉的工业短路试验.工业加热,1978,(3):1-4.
  • 4阎立懿,杨清潭.电弧炉短网的设计与改造[J].辽宁冶金,1994(1):22-27. 被引量:1
  • 5薛建民.电弧炉短网的电参数与节电.工业加热,1982,(3):1-4.
  • 6北京钢铁设计院.钢铁企业电力设计手册(下册)[M].北京:冶金工业出版社,1976:1159-1273.