摘要
采用以活性炭吸附分离,石墨炉原子吸收光谱法测定环境水样中的痕量铊。活性碳吸附后,用热的(NH4)2C2O4溶液进行淋洗分离,以0.06ug/LPdCl2溶液作为基体改进剂。检出限为2.65ng/L,线性范围0.00265~200ug/L,回收率为92.7%~99.0%。方法可用于环境水样中痕量铊的测定。
A fast and convenient method for the determination of trace thallium in water by GFAAS with activated carbon adsorption was established, and satisfactory results were achieved when thallium in water was determined by adsorption on activated carbon using hot (NH4)2 C2O4 as an eluent additives and 0.06 ug/mL PdCl2 as a matrix modifier. The detection limit was 2.65 ng/L, the linear range was 0.00265 - 200 ug/L, and the recoveries were 92.7%- 99.0%. The method is suitable for the determination of trace thallium in water with the advantages of simplicity, inex- pensiveness and no secondary pollution.
出处
《分析试验室》
CAS
CSCD
北大核心
2009年第9期56-58,共3页
Chinese Journal of Analysis Laboratory
基金
教育部科学技术研究重点(206135)
贵州省教育厅自然科学研究重点(黔教科2005106)项目资助