摘要 在简要介绍大口径平行光管测量系统的组成及工作原理的基础上,借助于该原理对光电测量装置进行了室内多光轴平行性标校测量,通过制作标准激光靶,利用感光相纸对激光光斑进行聚焦采集,实现了对电视/红外/激光三者光轴一致性的标校,使电视/红外光轴与激光光轴不平行度分别达到指标要求,取得了很好的效果. Based on introducing the form and the principle of the system for large-aperture collimator, the indoor emendation measurement of excessive optical axis parallelism for photo-electricity measuring equipment was done using the measurement principle. The optical axis parallelism emendation for TV/IR/Laser was implemented through fabricating standard laser target and collecting laser spot of the laser target by sensitive paper, so that the optical axis non-parallelism of TV/IR and Laser meets the technical index requirement, the good effect is realized.
机构地区 [
出处 《光电技术应用》 2009年第4期32-33,40,共3页 Electro-Optic Technology Application
关键词 平行光管 多光轴平行性 室内标校 激光靶(感光相纸) large-aperture collimator optical axis parallelism indoor emendation laser target