64排螺旋CT评估冠状动脉支架置入术效果的价值 被引量:12

Assessment of coronary stent lumen visibility and patency by 64-row MDCT in patients after coronary stent implanting
暂未订购
导出
摘要 目的:研究64排螺旋CT冠状动脉成像评价冠状动脉支架通畅性的价值。方法:对70例冠状动脉支架植入术后9~12个月患者行64排螺旋CT冠脉成像(共106个支架),观察支架及其支架血管的通畅性。采用5分制计分法评价支架的轴位多平面重建图像,同时测量支架内管腔直径。计算支架内管腔直径与支架近端的管腔直径比值。结果:图像平均质量达到优良水平。支架通畅85个(80.2%),支架内狭窄3个,闭塞1个,支架前后血管狭窄18个。平均支架内腔直径比率为(78.3±12.6)%。结论:64排螺旋CT可作为冠状动脉支架置入术后随访观察和了解冠心病进展情况的重要手段。 Objective: To evaluate the clinical value of assessment of coronary stent patency by 64 slice spiral CT in patients after coronary stent implanting. Methods: Totally 70 patients (106 stents) were investigated by 64 slice spiral CT. The image quality of stents were evaluated by a five scores scale and coronary lumen diameter. Stent lumen diameter was compared with the vessel diameter proximal of the stents to assess their stent lumen stenosis. Conventional coronary angiography was performed in 70 patients, and 106 stents were evaluated. Results: The image quality was good to excellent. The stent was easy and smooth in 85 cases (80.2%, 85/106). The average lumen diameter of stent was (78.3± 12.6)%. Conclusion: The 64 slice spiral CT is a useful tool to assess the coronary stent patency.
出处 《心血管康复医学杂志》 CAS 2009年第4期364-366,F0004,共4页 Chinese Journal of Cardiovascular Rehabilitation Medicine
基金 武警医学院院级课题(编号200812)
关键词 体层摄影术.X线计算机 冠状血管造影术 支架 Tomography, X--ray computed Coronary artery diseases Stents
  • 相关文献

参考文献9

  • 1Schuijf JD, Bax JJ, Jukema JW, et al. Nonivasive evaluation of the coronary arteries with multislice computed tomography in hypertensive patients [J].Hypertension, 2005, 45: 227- 232.
  • 2崔艳,钟丽华,白露,臧晓凤,王悦彤,张春玲.64排螺旋CT冠脉成像与冠脉造影对冠心病诊断的比较[J].心血管康复医学杂志,2008,17(3):245-247. 被引量:17
  • 3Rist C, Nikolaou K, Flohr T, et al. High-resolution exvivo imaging of stents using 64-slice computed tomography-initial experience [J]. Eur Radiol, 2006, 1564-1569.
  • 4Maintz D, Seifarth H, Raupach R, et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 difference stents [J]. Eur Radiol, 2005, 15: 1876-1881.
  • 5Mahnken AH, BueckerA, Wildberger JE, et al. Coronary artery stents in multislice computed tomography: in vitro artifact evaluation [J]. Invest Radiol, 2004, 39 (1): 272-331.
  • 6MaintzD, GrudeM, FallenbergEM, et al. Assessment of coronary arterial stents by multislice-CT angiography[J]. Acta Radiol, 2003, 44 (6): 597-603.
  • 7Kruger S, Mahnken AH, Sinha AM, et al. Multislice spiral- computed tomography for the detection of coronary stent rcstenosis and patency [J]. Intern J Cardiol, 2003, 89 (223): 1672- 1721.
  • 8Nieman K, Cademartiri F, Raaijmakers R, et al. Noninvasive angiographic evaluation of coronary stents with multi-slice spiral- computed tomography [J]. Herz, 2003, 28 (2): 1362-1421.
  • 9Schuijf JD, Bax JJ, Jukema JW, et al. Feasibility of assessment of coronary stent patency using 16 slice computed tomography [J]. Am J Cardiol, 2007, 94 (4): 4272-4301.

二级参考文献4

  • 1Brodoefel H, Reimann A, Heuschmid M, et al. Non-invasive coronary angiography with 16-slice spiral computed tomography:image quality in patients with high heart rates [J]. Eur Radiol, 2006, 16: 1434-1441.
  • 2Kuettner A, Christie B, Nicol R, et al. Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease[J]. AmJCardiol, 2006, 97: 173-174.
  • 3Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenosis with thin-slice multideteetor row spiral computed tomography and multiplanar teconstruction [J]. Circulation, 2003, 107 (1):664-666.
  • 4De Feyter PJ, Nieman K. New coronary imaging techniques: what to expect [J]. Heart, 2002, 87: 195-197.

共引文献16

同被引文献98

引证文献12

二级引证文献109

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部