通过对蓄能器保压夹紧回路的定量,给出了压力继电器的启闭压力,保证了夹紧力的可靠性,分析了蓄能器充气压力对保压时间的影响,给出了确定原则。
Through the quantitative analysis of accumulator press-keeping clamping circuit, given the pressure of the switch pressure of relay and the reliability of press-keeping clamping force, analyed the impact of pressure time from the inflation pressure of accumulator and given the determined principles.
出处
《煤矿机械》
北大核心
2009年第9期54-55,共2页
Coal Mine Machinery
关键词
夹紧回路
蓄能器
充气压力
继电器启闭压力
clamping circuit
accumulator
inflation pressure
switch pressure of relay