期刊文献+

科氏流量计测量信号采样与实时算法的实现 被引量:2

Implementation of Measuring Signal Sampling and Teal Time Algorithm in Coriolis Mass Flowmeter
在线阅读 下载PDF
导出
摘要 在分析科氏流量计输出信号特性对测量精度影响的基础上,从信号处理的角度,采用傅里叶频谱分析法,对影响测量精度的诸种因素进行分析处理,着重解决了在应用中的关键问题:用软件实现整周期采样,同时。 The signal processing in Coriolis mass flowmeter is studied. Based on the output signal properties of the flowmeter, the digital processing using the Fourier frequency domain analysis is adopted. The key measurement for improving precision of frequency and phase differences is taken, including raising frequency resolution and using integral periodic signal sampling. The software algorithm for periodic signal sampling is given. The real time sampling is also resolved with the aid of DFT algorithm.
作者 史福元
出处 《华中理工大学学报》 CSCD 北大核心 1998年第7期77-79,共3页 Journal of Huazhong University of Science and Technology
关键词 傅里叶变换 科氏流量计 整周期采样 实时算法 Fourier transform Coriolis mass flowmeter integral periodic signal sampling frequency resolution
  • 相关文献

参考文献3

  • 1徐科军,合肥工业大学学报,1996年,20卷,3期,20页
  • 2徐科军,电子测量与仪器学报,1995年,10卷,2期,24页
  • 3何振亚,数字信号处理的理论与应用,1982年

同被引文献20

  • 1徐科军,张瀚.一种科氏流量计的数字信号处理与驱动方法研究[J].计量学报,2004,25(4):339-343. 被引量:13
  • 2徐科军 吕迅 等.基于DFT的科氏流量计信号处理方法[J].中国科学技术大学学报,1998,28:180-183.
  • 3Romano P. Coriolis mass flow rate meter having a substantially increased noise immunity: U S Patent, No. 4934196. 1990
  • 4Yoshimura H. Phase difference measuring apparatus for measuring phase difference between input signals: European Patent Application ,EP 0791807A2. 27,08,1997
  • 5Yoshimura H. Phase difference measuring apparatus and flowmeter thereof: European Patent Application, EP 0702212A2.20,03,1996
  • 6Bose. Method and apparatus for measuring pressure in a Coriolis mass flowmeter: U S Patent , No. 5734112. 1998
  • 7Henry M P, Clarke D W, Vignos J H. Digital flowmeter: U S Patent , No. 2002/0038186A1. 2002
  • 8Henry, M. P. et al. A self - validating digital Coriolis massflow meter. IEEE Control Engineering Practice, 2000,8: 487 -506
  • 9Henry,M. P. et al. Pushing Coriolis to the limit. IEEE Computing and Control Engineering, 2003,6/7:24- 28
  • 10Freeman B S, Ashevillc N C. Digital phase locked loop signal processing for Coriolis mass flowmeter: U S Patent, No.5804741. 1998