双光束随机扫描准分子激光PRK临床初步评价

Clinical Results of Photorefractive Keratectomy for Correction of Myopia by Multiple Beam,Fractal,Random Projection Eximer Laser System
原文传递
导出
摘要 采用Kera公司生产ISOBEAMD—200准分子激光器,该系统包含“双光束随机投光”导光系统以及“非对称不规则”演算方法等许多新技术。它可以治疗各种屈光不正及纠正其它准分子述后后遗症,对一年以上的PRK病人进行了术后随访观察,矫正视力恢复快而稳定,不良反应少。结论为:该系统先进的工作模式,克服了其它激光系统常出现的中心岛与偏心岛问题。 To evaluate the early results of PRK for correction myopia with Isobeam D-200 laser system. In this paper we present a new 'random projection' delivery method. And new 'fractal algorithm' was also to achieve diopter-by-diopter ablation. 34 patients received PRK for myopia by Isobeam D-200system. Ingroup A (lessthan-3. 00D), B (between-3.00- -6. 00D )and C (more than-6. 00D), after 12 months follow-up, their mean uncorrected visual acuity were 0.97±0.25, 0.81±0.37,0.81±0.27 respectively. With TMS-2 examination,central island has not been dectected, no other complications occured. The results demonstrate kera's laser ststem has good predicability and lack of island side effect.
作者 李西凌 薛鹏
出处 《应用激光》 CSCD 北大核心 1998年第4期189-190,188,共3页 Applied Laser
关键词 双光束随机投光 PRK LASIK 激光术 random projection, fractal algorithm, island effects