期刊文献+

过氧化氢低温等离子体灭菌技术在牙科手机应用的探讨 被引量:3

Application of Low Temperature Hydrogen Peroxide Gas Plasma Sterilization in Dental Handpieces
原文传递
导出
摘要 目的探讨过氧化氢低温等离子体灭菌法应用于牙科手机灭菌。方法240支牙科手机按照注油方式和包装方式不同,分为8组,经强生STERRAD 100S过氧化氢低温等离子体灭菌器灭菌后,通过无菌检验检测灭菌效果,并进行转速检测和外观检查。结果自动注油组灭菌后的牙科手机在4种包装形式下,无菌检验均无菌生长,灭菌效果可靠;牙科手机经10次过氧化氢等离子体灭菌循环,转速无明显下降,外观完好,无明显氧化现象。结论过氧化氢低温等离子体灭菌牙科手机灭菌效果可靠,未见牙科手机机械性能损耗。 OBJECTIVE To investigate the application of low temperature hydrogen peroxide gas plasma sterilization in dental handpieces. METHODS Totally 240 pieces dental handpieces were divided into 8 groups in accordance with different ways of oiling and package, sterilized by Johnson STERRAD 100S low temperature hydrogen peroxide gas plasma sterilizer, and then inspected by sterility testing, rotational speed and appearance observation. RESULTS The result of sterility testing of dental handpieces in auto oiling group with 4 types of packages was negative, and the sterilization effect was reliable. After 1O cycles of low temperature hydrogen peroxide gas plasma sterilization, the rotational speed of dental handpieees had no obvious decline and the appearance was quite intact without any corrosion. CONCLUSIONS The sterilization effect is reliable and the damage caused by low temperature hydrogen peroxide gas plasma sterilization on dental handpieces is not found.
出处 《中华医院感染学杂志》 CAS CSCD 北大核心 2009年第16期2133-2135,共3页 Chinese Journal of Nosocomiology
关键词 低温 等离子体 灭菌 口腔 牙科手机 Low temperature Plasma Sterilization Stomatology Handpieees
  • 相关文献

参考文献6

二级参考文献43

  • 1孟月东.低温等离子体灭菌技术[J].中国医疗器械信息,2004,10(5):4-6. 被引量:37
  • 2顾春英,薛广波.等离子体消毒和灭菌[J].上海预防医学,1999,11(11):486-491. 被引量:18
  • 3李真,臧晓丽,刘颖,张亚莲.产超广谱β-内酰胺酶革兰阴性菌对12种抗菌药物耐药性分析[J].中华医院感染学杂志,2004,14(2):217-219. 被引量:55
  • 4丛莉.环氧乙烷灭菌的研究进展[J].医疗装备,2004,17(12):17-18. 被引量:8
  • 5黄靖雄.环氧乙烷灭菌[J].中华医院感染学杂志,2004,14(12):1435-1439. 被引量:68
  • 6Lerouge S, Guignot C, Tabrizian M, et al. Plasma-based sterilization:effect on surface and bulk properties, and hydrolytic stability of reprocessed polyurethane electrophysiology catheters[J]. J Biomed Mater Res, 2000, 52(4): 774-782.
  • 7Herrmann H W, Henins I, Park J, et al. Decontamination of chemical and biological warfare (CBW) agents using an atmospheric pressure plasma jet (APPJ)[J]. Phys Plasmas, 1999, 6(5): 2284-2289.
  • 8Laroussi M, Richardson J P, Dobbs F C. Effects of non-equilibrium atmospheric pressure plasma on the heterotrophic pathways of bacteria and on their cell morphology[J]. Appl Phys Lett, 2002, 81(2): 772-774.
  • 9Moisan M, Barbeau J, Moreau S, et al. Low temperature sterilization using gas plasmas: a review of the experiments, and an analysis of the inactivation mechanisms[J]. Int J Pharmaceutics, 2001, 226(5): 1-21.
  • 10Feldman LA, Hui HK. Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma[J]. Med Device Diagnos Indust, 1997,19(12):57-62.

共引文献126

同被引文献17

引证文献3

二级引证文献31

相关作者