期刊文献+

光学读出红外成像中反光板变形对光学检测灵敏度的影响

EFFECT OF REFLECTOR DEFORMATION ON OPTICAL DETECTION SENSITIVITY FOR OPTICAL READOUT INFRARED IMAGING SYSTEM
在线阅读 下载PDF
导出
摘要 在刀口滤波光学读出方法的基础上,讨论了反光板弯曲的情况下,刀口滤波方法的光学检测灵敏度与反光板长度之间的关系.分析表明,在反光板曲率半径一定的情况下,光学检测灵敏度首先随着反光板长度的增加而增大,达到最大值后随着反光板长度的增加而减小.对于不同曲率半径和长度的反光板,分析给出反光板长度L和曲率半径R在满足L2/R=λ(λ为照明光波长)时,光学检测灵敏度达到最大值.实验测量了已制作的像素尺寸分别为200μm,120μm和60μmFPA的光学检测灵敏度,其实验结果和理论分析一致. Based on the optical readout method with knife edge filter, the relationship between the optical detection sensitivity and reflector length was discussed under the circumstance that the reflector was bent. Analysis indicates that the optical sensitivity increases with the reflector's lengthening at first, then it reaches a maximum value, and then it decreases as the reflector continues to lengthen. For the reflectors with different curvature radii and lengths, analysis shows that the sensitivity will reach a maximum value when the expression L^2/R = A (L is length of reflector, R is curvature of the reflector, A is wavelength of illumination light) is satisfied. The optical detection sensitivities of the fabricated FPAs with different pixel sizes as 200μm, 120μm and 60μm were obtained experimentally. The result coincides with the theoretical analysis.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2009年第4期249-253,共5页 Journal of Infrared and Millimeter Waves
基金 自然科学基金仪器专项基金(10627201) 重点基金(10732080) 国家重大基础研究计划(2006CB300404)资助项目
关键词 非制冷红外成像 双材料微悬臂梁 光学读出 焦平面阵列 uncooled infrared imaging bi-microcantilever optical readout FPA
  • 相关文献

参考文献7

  • 1Zhao Y, Mao M, Horowitz R, et al. Optomechanical uncooled infrared imaging system: design, microfabrication and performance[ J]. J. MEMS,2002,11(2) : 136--146.
  • 2DUAN Zhi-Hui, ZHANG Qing-Chuan, WU Xiao-Ping, et al. Uncooled optically readable bimaterial micro-cantilever infrared imaging device [ J ]. Chin. Phys. Lett., 2003,20 (12) :2130--2132.
  • 3MIAO Zheng-Yu, ZHANG Qing-Chuan, GUO Zhe-Ying, et al. Optical readout method for microcantilever array sensing and its sensitivity analysis [ J ]. Opt. Lett. , 2007,32 (6), 594--596.
  • 4郭哲颖,张青川,陈大鹏,伍小平,董凤良,缪正宇,熊志铭,李超波.光学读出室温物体红外成像[J].实验力学,2005,20(2):213-218. 被引量:10
  • 5董凤良,张青川,伍小平,潘亮,郭哲颖,陈大鹏,王玮冰,段志辉.双材料微梁阵列非制冷红外成像系统——微梁阵列的设计与制作[J].红外与毫米波学报,2005,24(6):409-413. 被引量:8
  • 6Stoney G G. The tension of metallic films deposited by electrolysis[C]. London:procRoy. Soc. A, 1989,82,172- 175.
  • 7Lin I K,ZHANG Yan-Hang, ZHANG Xin. The deformation of microcantilever-based infrared detectors during thermal cycling [ J ]. J. Micromech. Microeng ,2008 ,18 ,075012.

二级参考文献18

  • 1潘亮,张青川,伍小平,段志辉,陈大鹏,王玮冰,郭哲颖.基于MEMS的光力学红外成像[J].实验力学,2004,19(4):403-407. 被引量:22
  • 2Antoni Rogalski. Infrared detectors:status and trends[J]. Progress in Quantum Electronics,2003,27:59-210.
  • 3Zhao Y. Optomechanical uncooled infrared imaging system [D]. Dissertation of UC, Berkeley, 2002.
  • 4Mao, M, Perazzo, T, Kwon, O, et al. Direct-view uncooled micro-optomechanical infrared camera [C]. In MEMS '99. Twelfth IEEE International Conference USA:orlando, Florida, 1999,100-105.
  • 5Senesaca L R, Corbeila J L, Rajicab B S, et al. IR imaging using uncooled microcantilever detectors [J]. Ultramicroscopy, 2003,97:451-458.
  • 6Zhao Y, Mao M, Horowitz R, et al. Optomechanical uncooled infrared imaging system: Design, microfabrication, and performance [J]. J. of MEMS., 2002,11(2):136-146.
  • 7Lai J, Perazzo T, Shi Z, et al. Optimization and Performance of High-resolution Micro-optomechanical Thermal Sensors [J]. Sensors and Actuators A,1997,58:113-119.
  • 8Biao Li. Design and simulation of an uncooled double-cantilever microbolometer with the potential for ~mK NETD [J]. Sensors and Actuators A,2004,112:351-359.
  • 9Oden P I, Datskos P G, Thundat T, et al. Uncooled thermal imaging using a piezoresistive microcantilever[J]. Appl. Phys. Lett., 1996, 69(21):3277~3279
  • 10Manalis S R, Minne S C, Quate C F, et al. Two-dimensional micromechanical bimorph arrays for detection of thermal radiation [J]. Appl. Phys. Lett., 1997, 70(24): 3311~3313

共引文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部