摘要
文中提出的设计构想是当某座杆塔发生绝缘闪络时,监测系统能够自动的将线路名称、故障杆塔的塔号等信息,以无线传输的方式发送给监控中心,指导线路维护人员及时、准确地进行故障检查或维修,从而大大降低线路维护人员的劳动强度,节约开支,减少线路的潜在隐患和停电时间,提高输电线路的安全可靠性。
This paper presents a thinking which can automatically monitor and orient transmission line insulation flashover when a tower block insulation flashover occurred. The monitoring system is able to record the information of the line timely and accurately, and then send it to the monitoring center by wireless transmission. With the information, the staff can decide which line has need to maintain and it can reduce the cost and the labor of staff. So it can discover the potential danger, reduce the time of power-off and improve security and reliability on transmission line.
出处
《信息技术》
2009年第7期198-200,共3页
Information Technology
关键词
线路故障
闪络
监测
定位
line fault
flashover
monitoring
orientation