期刊文献+

细水雾灭火系统在图书馆的应用研究 被引量:4

The application of water mist extinguishing system in library
在线阅读 下载PDF
导出
摘要 图书馆内保存有大量的珍贵资料和书籍,一旦发生火灾损失无法估计。图书馆由于其特殊性对火灾保护系统也有特殊的要求。通过细水雾灭书架火的模拟实验,表明了细水雾能够快速有效地抑制图书库火灾,但完全扑灭受书架遮挡的小火则需较长时间。 There are a large amount of valuable files and books stored in the library, once fire occurs, the loss will be enormous. Due to the particularities of library, the requirements to the fire protection system are also specific. According to the results of the simulation test using water mist system to extinguish fire on bookshelves, the water mist can suppress the fire in library effectively and rapidly, but it still need longer time to thoroughly extinguish the fire hind by the bookshelves form view.
作者 赵力增 钱芳
出处 《消防科学与技术》 CAS 北大核心 2009年第6期421-424,共4页 Fire Science and Technology
关键词 细水雾 灭火系统 灭火实验 图书馆 water mist fire extinguishing system fire extinguishing simulation test library