摘要
以实验数据为基础,分析了外界环境温度变化和冷凝侧出水温度变化对空气源热泵热水器压缩机耗功、COP、压力比、质量流量等性能参数的影响,为系统性能的进一步提高提供了理论依据。
The variety of environment and outlet of condenser side temperature's influence on performance parameters of air source pump water heater were analyzed based on experimental data,which mainly included consumption and pressure ratio of compressor,COP, mass flow and so on. It provided theory basis for the further improvement of the performance of the system.
出处
《制冷空调与电力机械》
2009年第3期1-4,共4页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
空气源热泵热水器
实验
环境温度
冷凝侧出水温度
air source pump water heater
experiment
environment temperature
condensing water temperature