摘要 介绍一种新颖的激光测浊仪的原理、结构、技术指标及特点,并结合测浊原理和仪器特点对浊度测定的方法作了探讨。该仪器为实验室型柱积分式散射光测浊仪,以He-Ne激光为光源,以蠕动泵为输液动力用微型管路构成分析流程、用微机(8098)数据处理使仪器的最小分度达0.01福马肼(Formazine)浊度单位。 おhe principle,structure,technical index and features of a new laser turbidimeter are described.In addition,the method to survey turbidity is discussed in combination with the principle of turbidity measurement and features of the instrument.The meter is of laboratory pattern and measuring turbidity by column integration and scattering light.The light source is a He-Ne laser.Sample solution is transported continuously by a peristaltic pump and the analytic process is composed with minipiping.The analytical data are finally processed by a microcomputer(8098).The resolution of the meter is 0.01 Folmazine.
出处 《东北电力学院学报》 1998年第2期98-106,共9页 Journal of Northeast China Institute of Electric Power Engineering
关键词 浊度计 散射光 透射光 测浊仪 激光测浊仪 laser,scattering light,transmitting light,turbidimeter
  • 相关文献

参考文献1

  • 1[日]荒木峻 编,赵连生.水污染的自动分析[M]中国建筑工业出版社,1982.

同被引文献28

  • 1林晓东.浊度仪计算机系统中的数字滤波算法[J].福建农林大学学报(自然科学版),2004,33(1):133-136. 被引量:2
  • 2韩国才,张锂,吴传琳.全积分智能液体在线浊度仪的研制与应用[J].工业水处理,2005,25(4):59-60. 被引量:2
  • 3曹顺安.火电厂高纯水中小硬度测定方法研究-痕量钙的FIA分光光度法,迈向二十一世纪的中国电力技术.94’全国青年电力系统学术会议文集[M].武汉:湖北科学技术出版社,1994..
  • 4潘宏泽.FIA在监控火力发电厂水、汽质量中的应用.第四届全国流动注射分析学术报告会论文集[M].武汉,1993..
  • 5曹顺安.痕量硅、微量磷的离子交换富集-流动注射分析方法的同时测定.第一届全国流动注射分析学术报告会论文集[M].沈阳,1987..
  • 6勤编.离子选择性电极分析法[M].北京:人民教育出版社,1980..
  • 7方肇仑.流动注射分析,分析化学前沿[M].北京:科学出版社,1991..
  • 8李永生.电厂炉水磷酸盐的流动注射分光光度法[J].工业水处理,1986,6(3).
  • 9高经伍 赵凤华.Cl^-浓度测量仪[A]..第三届全球智能控制与自动化大会[论文集].合肥:中国科技大学出版社,2000..
  • 10Hong zhietal. On-line Turbidity Measurement[J]. Using Surface Scattering. SPIE 3558,1998,28 - 30.

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部