摘要 针对国华绥中电厂800MW机组锅炉空气预热器(空预器)漏风率高达30%的现状,进行了密封结构的改造。对单密封、双密封和柔性接触式密封3种方案分析比较后,认为柔性接触式密封可弥补转子的变形缺陷,对转子驱动系统和转子结构受力影响很小,且改造工作量小,检修工艺简单,效果好。改造实施后,空预器的漏风率降至10%以下,明显提高了锅炉效率,在安全性和经济性方面都取得了预期效果。 This paper introduces the seal retrofitting of air preheater PBII- 13.8 of the 800 MW boiler of the Guohua Suizhong Electric Power Plant. According to the structure of this preheater, the author analyzes the reasons of the air leakage, contrasts the reconstruction projects and analyzes the holistic flexible contactile of seal retrofits. After the retrofit, the tests of the preheater air leakage condition have been taken under several working circumstances, and expected effects have been achieved. The air leakage rate has decreased to less than 10%. At the same time,economic evaluation has been made for this retrofit.
作者 邹海峰 李英
出处 《热力发电》 CAS 北大核心 2009年第5期56-58,共3页 Thermal Power Generation
关键词 锅炉 空预器 漏风 柔性接触式 密封 改造 air preheater, seal, reconstruction, the major projects
  • 相关文献

参考文献3

二级参考文献6

  • 1何世言.淮北国安电力公司1号机组大修前锅炉热力试验报告[R].安徽省电力试验研究所,2003..
  • 2何世言.淮北国安电力公司1号机组大修后锅炉热力试验报告[R].安徽省电力试验研究所,2003..
  • 3范从振.锅炉原理[M].北京:水利电力出版社,1992..
  • 4陈增宏.上海闵行发电厂8号炉空气预热器改造后性能试验报告[R].华东电力试验研究院,2005.
  • 5陈增宏.上海闵行发电厂10/11号炉空气预热器改进后性能测试与评价[R].华东电力试验研究院,2006.
  • 6刘贵锋.回转式空气预热器密封形式的改进[J].热能动力工程,2001,16(2):208-210. 被引量:6