期刊文献+

OCT在原发性急性闭角型青光眼中的应用 被引量:2

Application of OCT in acute primary angle-closure glaucoma
原文传递
导出
摘要 目的应用光学相干断层扫描仪(OCT)测量原发性急性闭角型青光眼(APACG)视网膜神经纤维层(RNFL)厚度,观察其变化规律。方法应用OCT测量首次急性发作(<6 h)的APACG患者(26例)RNFL厚度的改变,测量时间为入院经治疗角膜透明后当天和经治疗眼压下降至正常范围后1周、1个月、3个月、6个月(共5次)。同时测量正常成人(年龄匹配,30例)的RNFL厚度作为对比。结果入院经治疗角膜透明当天和眼压正常后1周平均RN-FL厚度分别为(122.14±21.37)(、110.25±17.43)μm,较正常对照组增厚(P<0.01,P<0.05);眼压正常后1个月平均RNFL厚度为(103.34±15.19)μm,较正常稍增厚(P>0.05);眼压正常后3个月和正常后6个月平均RNFL厚度分别为(102.56±14.11)(、101.22±15.54)μm,较正常对照组稍下降(P>0.05)。结论眼压急性升高在早期造成RNFL水肿,RNFL厚度增厚,经过治疗眼压降至正常范围后,RNFL厚度逐渐下降。眼压正常后3个月和6个月RNFL厚度趋于稳定。 Objective To explore the change law of the retinal nerve fiber layer (RNFL) thickness in acute primary angle-closure glaucoma (APACG). Methods 26 subjects of APACG with the first acute attack( 〈 6 hours) and 30 normal controls were included in this study. The RNFL thickness was accessed by optical coherence tomography (OCT)on the 1st day when the cornea became clear and at 1 week, 1 month, 3 months,and 6 months after intraecular pressure(IOP) was controlled(5 times ). RNFL thickness was compared between attacked eyes and normal control eyes. Results RNFL thickness on the 1st day of corneal transparency( 122.14 ± 21.37)tnn was thicker than that of normal controls( P 〈 0.01 ). At 1 week after IOP was controlled, RN- FL thickness ( 110.25 ± 17.43)μm was thicker than that of normal controls ( P 〈0.05). At 1 month after IOP was controlled, RNFL thickness ( 103.34 ± 15.19)μm was a httle thicker than that of normal controls ( P 〉 0.05), there was no significant difference. At 3 months ( 102.56 ± 14.11 )/an and 6 months ( 101.22 ± 15.54 ) μm after IOP was controlled, RNFL thickness was a little thinner than that of normal control ( P 〉 0.05) , and there were no significant differences. Conclusion In the early period, acute rising of IOP caused edema of the retina, and RNFL became thicker. After IOP decreased to a normal range, RNFL became thinner. At 3 and 6 months after IOP was controlled, the RNFL thickness tended to be stable.
出处 《山东大学耳鼻喉眼学报》 CAS 2009年第2期86-88,共3页 Journal of Otolaryngology and Ophthalmology of Shandong University
关键词 青光眼 闭角型 光学相干断层扫描 视网膜神经纤维层 Glaucoma, Angle-Closure Optical coherence tomography Retinal nerve fiber layer
  • 相关文献

参考文献13

  • 1Sommer A, Miller N R, Pollack I. The nerve fiber layer in the diagnosis of glaucoma [J]. Arch Ophthalmol, 1977, 95(12): 2149-2156.
  • 2Fang A W, Qu J, Li L P, et al. Measurement of retinal nerve fiber layer in primary acute angle closure glaucoma by optical coherence tomography[J]. J Glaucoma, 2007, 16(2) : 178- 184.
  • 3Massin P, Vicaut E, Naouchone B, et al. Reproducibility of retinal mapping using optical coherence tomography[ J]. Arch Ophthalmic. 2001. 119(8) : 1135-1142.
  • 4Goebel W, Kretzchmar-Gross T. Retinopathy: a study using optical coherence tomography (OCT) [J]. Retina, 2002, 22 (6) : 759-767.
  • 5Schuman J S, Pedut-Kioizman T, Hertzmark E, et al. Repro- ducibility of nerve fiber layer thickness measurements using optical coherence tomography [ J ]. Ophthalmology, 1996, 103 (11) : 1889-1898.
  • 6葛坚,骆荣江,刘杏,王梅.光学相干断层成像术检测视网膜神经纤维层厚度的初步研究[J].中国实用眼科杂志,1999,17(6):331-335. 被引量:22
  • 7Mok K H, Lee V W, So K F. Retinal nerve fiber layer measurement of the Hong Kong Chinese population by optical coherence tomography[ J]. J Glau, 2002, 11 (6) :481-483.
  • 8Hayreh S S. Blood supply of the optic nerve head and its role in optic atrophy, glaucoma, and edema of the optic disc[J]. Br Ophthalmol, 1969, 53(11) :721-748.
  • 9Tso M O, Hyreh S S. Optic disc edema in raised intracranial pressure. III . A pathologic study of experimental papilledema [J].Arch Ophthalmol, 1977, 95(8):1448-1457.
  • 10Tsai J C. Optical coherence tomography measurement of retinal nerve fiber layer after acute primary angle closure with normal visual field [J]. Am J Ophthalmol, 2006, 141(5): 970-972.

二级参考文献15

  • 1孙兴怀.原发性闭角型青光眼的特点再认识[J].眼科,2006,15(2):76-78. 被引量:17
  • 2Harry AQ, Earl MD, et al. Optic nerve damage in human glaucoma: Ⅲ. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropa- thy. Arch ophthalmol, 1982,100:135-146.
  • 3Schuman JS. Optical coherence tomography for imaging and quantification of the nerve fiber layer thickness. In : Schuman JS, ed. Imaging in Glaucoma. Thorofare, NJ: SLACK, 1996: 7.
  • 4Leonard W. Yip, Vernon K. Y. Yong, et al. Optical coherence tomography of optic disc swelling in acute primary angle-closure glaucoma. Acta Ophthalmol, 2006, 123 : 567-569.
  • 5Fang AW, Qu J, et al. Measurement of retinal nerve fiber layer in primary acute angle closure glaucoma by optical coherence tomography. J Glancoma, 2007,16:178-184.
  • 6Jen-Chia Tsai. Optical coherence tomography measurement of retinal nerve fiber layer after acute primary angle closure with normal visual field. Am J Ophthalmol, 2006,141:970-972.
  • 7Ting Aung, Rahat Husain, et al. Changes in retinal nerve fiber layer thickness after acute primary angle closure. Ophthalmology, 2004,111:1475-1479.
  • 8Kerringan-Baumrind LA, Quigly HA, et al. Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons. Invest Ophthalmol Vis Sci, 2000,41:741-748.
  • 9Hayreh SS. Blood supply of the optic nerve head and its role in optic atrophy, glaucoma, and edema of the optic disc. Br Ophthalmology, 1969,53:721-748.
  • 10Chaudhry IM, Moster MR, et al. Iris ring melanoma masquerading as pigmentary glaucoma. Arch Ophthalmol, 1997,115:1480-1481.

共引文献28

同被引文献17

  • 1Gadi Wollstein,Joel S. Schuman,Lori L. Price,Ali Aydin,Paul C. Stark,Ellen Hertzmark,Edward Lai,Hiroshi Ishikawa,Cynthia Mattox,James G. Fujimoto,Lelia A. Paunescu,刘春(译),朱志忠(校).青光眼视网膜神经纤维层厚度的光学相干断层扫描纵向评估[J].美国医学会眼科杂志(中文版),2005,17(4):214-220. 被引量:14
  • 2Marschall S, Sander B, Mogensen M, et al. Optical coherence tomo- graphy-current technology and applications in clinical and biomed- ical research. Anal Bioanal C hem, 2011,400 ( 9 ) : 2699 -2720.
  • 3Hood DC, Raza AS. Method for comparing visual field defects to lo- cal RNFL and RGC damage seen on frequency domain OCT in pa- tients with glaucoma. Biomed Opt Express ,2011,2 (5) : 1097-1105.
  • 4Garas A, Vargha P, Hol16 G. Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma. Eye (Land) ,2011,25 ( 1 ) :57-65.
  • 5Gabriele ML, Wollstein G, Ishikawa H, et al. Optical coherence tomography : history, current status, and laboratory work. Invest Ophthalmol Vis Sci,2011,52(5) :2425-2436.
  • 6Vizzeri G, Weinreb RN, Gonzalez-Garcia AO, et al. Agreement between spectral-domain and time-domain OCT for measuring RN- FL thickness. Br J Ophthalmol,2009,93(6) :775-781.
  • 7Kotowski J, Wollstein G, Folio LS, et al. Clinical use of OCT in assessing glaucoma progression. Ophthalmic Surg Lasers Imaging, 2011,42 Suppl : $6-S14.
  • 8Chang PT, Sekhon N, Budenz DL, et al. Effect of lowering in- traocular pressure on optical coherence tomography measurement of peripapillary retinal nerve fiber layer thickness. Ophthalmology, 2007,114(12) :2252-2258.
  • 9Aydin A, Wollstein G, Price LL, et al. Optical coherence tomo- graphy assessment of retinal nerve fiber layer thickness changes af- ter glaucoma surgery. Ophthalmology,2003,110 ( 8 ) : 1506-1511.
  • 10刘义戈,刘华.光学相干断层扫描在眼科临床应用的研究进展[J].医学综述,2007,13(24):2014-2016. 被引量:8