摘要 目的对比磁共振胆管水成像(T2WI—MRC)和莫迪司对比增强磁共振胆管造影(CE—MRC)对肝移植供体的胆管显示的差别。方法32例肝移植供体,其中男性18例,女性14例,年龄21~63岁,平均年龄35岁。术前行MRC水成像和莫迪司增强后胆管造影检查.对两种检查方法显示肝内外胆管的优缺点进行比较。所有肝移植供体均行术中胆管造影检查。结果2种方法均可清楚显示3级肝内胆管.但T2WI—MRC显示肝内3级以上胆管明显优于CE—MRC(P〈0.05)。T2WI—MRC有5例(15.6%)供体肠道内液体影响胆管显示.CE—MRC则无一例供体肠道液体影响胆管显示。呼吸引起的运动伪影两种检查方法均不明显。胆管变异9例,两种检查方法均正确诊断。2例供体T2WI—MRC显示胆总管不连续,CE—MRC及术中胆管造影显示胆总管正常。结论T2WI—MRC和CE—MRC均可用来评估术前活体肝移植供体胆管解剖,两种检查方法各有优缺点.联合应用将明显提高其诊断准确性。 Objective To compare conventional T2-weighted magnetic resonance cholangiography (T2WI-MRC) with Muhihanceenhanced T1-weighted magnetic resonance cholangiography (CE-MRC) for evalution of biliary anatomy in liver transplant donor candidates. Methods A total of 32 healthy liver transplant donor candidates, male 18, female 14, aged 21 - 63 years, mean age 35 years, were examined with two kinds of MR cholangiographic methods. For T2WI-MRC, the three-dimensional turbo spin-echo sequence and oblique coronal heavily T2-weighted thick-slab turbo spin-echo imaging sequence were performed. For CE-MRC, three-dimensional fat-suppressed spoiled gradient-echo sequences were performed, one in the coronal plane and the other in the axial plane, with a time delay of 60 minutes after the administration of Muhihance. Intraoperative cholangiography was the reference-standard examination for liver transplant donor. Results The two methods showed the third branches intrahepatic biliary tract clearly. But the T2WI-MRC was displayed significantly superior to CE-MRC in interhepatic biliary upper the third branches (P 〈 0.05). Intestinal liquid influenced the image of biliary tract in five cases performed with T2WI-MRC, but no case in CE-MRC. The respirtory motion artifact was not obvious in 2 methods, both methods were able to make correct diagnosis in 9 cases of diagnose the biliary anatomic variants. T2WI-MRC showed common bile ducts intermit in 2 cases, but there were normal in CE-MRC and intraoperative cholangiography. Conclusion T2WI-MRC and CE-MRC could be used to evaluate biliary anatomy of liver transplant donor candidates. There are advantages and disadvantages to each approach, the combined application of 2 methods could significantly improve the accuracy of diagnosis.
出处 《生物医学工程与临床》 CAS 2009年第3期193-197,共5页 Biomedical Engineering and Clinical Medicine
基金 武警总医院科研基金(WZ2008008)
关键词 活体肝移植 莫迪司 磁共振胆管造影术 living donor liver transplantation Muhihance magnetic resonance cholangiography
  • 相关文献

参考文献16

  • 1严律南.活体肝移植的现状与展望[J].中国普外基础与临床杂志,2007,14(2):128-131. 被引量:23
  • 2Limanond P,Raman SS,Ghobrial RM,et al.The utility of MRCP in preoperative mapping of biliary anatomy in adult-toadult living related liver transplant donors[J].J Magn Reson Imaging,2004,19(2):209-215.
  • 3An SK,Lee JM,Suh KS,et al.Gadobenate dimeglumine-enhanced liver MRI as the sole preoperative imaging technique:a prospective study of living liver donors[J].AJR Am J Roentgenol,2006,187(5):1223-1233.
  • 4Lim JS,Kim M J,Kim JH,et al.Preoperative MRI of potential living-donor-related liver transplantation using a single dose of gadobenate dimeglumine[J].A JR Am J Roentgenol,2005,185(2):424-431.
  • 5Lee VS,Krinsky GA,Nazzaro CA,et al.Defining intrahepatic biliary anatomy in living liver transplant donor candidates at mangafodipir trisodium-enhanced MR cholangiography versus conventional T2-weighted MR cholangiography[J].Radiology,2004,233(3):659-666.
  • 6Sirvanci M,Duran C,Ozturk E,et al.The value of magnetic resonance eholangiography in the preoperative assessment of living liver donors[J].Clin Imaging,2007,31 (6):401-405.
  • 7Song GW,Lee SG,Hwang S,et al.Preoperative evaluation of biliary anatomy of donor in living donor liver transplantation by conventional nonenhanced magnetic resonance cholangiography[J].Transpl Int,2007,20(2):167-173.
  • 8Kim RD,Sakamoto S,Haider MA,et al.Role of magnetic resonance eholangiography in assessing biliary anatomy in right lobe living donors[J].Transplantation,2005,79 (10):1417-1421.
  • 9吴戈,曾庆玉,班润义,霍建伟,罗凌飞,王成纲,尹晓明,李宝平.HASTE序列磁共振胰胆管成像:单层和多层法成像技术比较研究[J].实用放射学杂志,2004,20(3):241-244. 被引量:12
  • 10孙昌进,周翔平,杨志刚,熊燕,宋彬,陈宪,张刚.MRCP诊断术后胆管结石:2D、3DFASE序列对照[J].实用放射学杂志,2005,21(2):143-146. 被引量:6

二级参考文献29

  • 1王学浩,杜竞辉,张峰,李相成,赵翰林,赵志泉,武正炎,眭元庚,徐鑫荣,张国楼,傅成章,钱建民,孙跃明,刘越健,张茂金.活体供肝原位部分肝移植一例报告[J].中华器官移植杂志,1995,16(3):133-134. 被引量:55
  • 2严律南,李波,曾勇,文天夫,赵纪春,王文涛,杨家印,徐明清,马玉奎,陈哲宇,吴泓.成人间活体肝移植研究[J].四川大学学报(医学版),2006,37(1):88-92. 被引量:24
  • 3[1]Wallner BK, Schumacher KA, Weidermaier W, et al. Dilated biliary tract: evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence[J].Radiology, 1991, 181(3): 805-808.
  • 4[2]Reinhold C, Bret PM. Current status of MR cholangiopancreatography[J].AJR,1996,166(6): 1285-1295.
  • 5[3]Morimoto K, Shimoi M, Shirakawa T, et al. Biliary obstruction: evaluation with three-dimensional MR cholangiography[J].Radiology,1992,183(2): 578-580.
  • 6[4]Soto JA, Barish MA, Yucel EK, et al. MR cholangiopancreatography: findings on 3D fast spin-echo imaging[J].AJR,1995,165(6): 1397-1401.
  • 7[5]Barish MA, Yucel EK, Soto JA, et al. MR cholangiopancreatography: efficacy of three-dimensional turbo SE technique[J].AJR,1995,165(2): 295-300.
  • 8[6]Chan YL, Chan AC, Lam WW, et al. Choledocholithiasis: comparison of MR cholangiography and endoscopic retrograde cholangiography[J].Radiology, 1996, 200(1): 85-89.
  • 9[7]Takehara Y, Lchijo K, Tooyama N, et al. Breath hold MR cholangiopancreatography with a long echo-train fast SE sequence and a surface coil in chronic pancraetitis[J].Radiology, 1994,192(1): 73-78.
  • 10[8]Kiefer B. Spin-echo and dynamic gadoliaium-enhanced FLASH MR imaging of the patocellular carcinoma: correlation with histopathologic findings[J].JMRI, 1994,4(1): 86-87.

共引文献35

同被引文献51

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部