摘要 利用KCI-Cu(Ⅱ)-EDTA缓冲溶液电解质体系发生CuCl研究了载金炭中金的精密测定。讨论了提高试样中测定金准确度和精密度的途径。结果表明,当载金炭中金品位大约为4000g/t时,金的回收率在98%-101.2%之间,RSD=1.85%(n=6)。 The precise coulometric titration of gold in carrying gold carbon was carried out with electrogenerated* chlorocuprous ion in KCl-Cu-EDTA buffer medium. Some ways of increasing the accuracy and precision for the*determination of gold were discussed in detail The results showed that the recovery is between 98.0%-101.2%,and the* relative standard is 1.85% (n=6) when gold content is about 4000g/t.*
出处 《冶金分析》 CAS CSCD 北大核心 1998年第3期19-2,共1页 Metallurgical Analysis
关键词 库仑滴定 载金炭 氯化钾 EDTA Coulometric titration, Gold, Carrying gold carbon