通过对CEFR虹吸破坏装置的设备结构分析及其两相流泄漏过程研究,进而对非能动方式减少液钠泄漏量的过程有更深入地了解。通过数值模拟计算结果与实验数据的对比表明,该数值模型较好的描述了虹吸破坏装置的泄漏过程。
According to the study of CEFR anti-siphon equipment structure and its twophase flow phenomenon, we can deeply understand its passive function which could be used to reduce the leakage of sodium. Compared to the experimental data, a numerical model can correctly describe this phenomenon of leakage processes.
出处
《核科学与工程》
CSCD
北大核心
2009年第1期33-38,共6页
Nuclear Science and Engineering
关键词
中国实验快堆
虹吸破坏装置
两相流
非能动
China Experimental Fast Reator
passive anti-siphon equipment
two-phase flow