摘要 目的分析体循环血管阻力(SVR)异常在健康人群中的分布特点及心脏功能参数的相关变化。方法用Bioz.com数字化无创血液动力学监护仪,观察919名健康人体循环血管阻力及平均动脉压(MAP)、心输出量(CO)、心脏指数(CI)、搏出量(SV)、搏出指数(SI)、左心做功量(LCW)等心功能参数。结果体循环血管阻力异常在低年龄段和高年龄段发生率均较高;女性显著高于男性(P<0.001)。相关因素分析显示,体循环血管阻力与平均动脉压(MAP)、脉压(PP)和左心射血时间(LVET)呈正相关;而与心输出量、心脏指数、搏出量、搏出指数、左心做功量及动脉顺应性(AC)呈负相关。结论广西壮族自治区人群体循环血管阻力异常与年龄、性别及血压水平密切相关,体循环血管阻力升高,心输出量和心指数降低,心脏泵功能减弱。 Objective To analyze the distribution features of systemic vascular resistance(SVR) disorder in healthy subjects at Guangxi province. Methods SVR and systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure(MAP), pulse pressure (PP), cardiac output (CO) , cardiac index(CI), stroke volume(SV), stroke index(SI) ,left ventricular ejection time (LVET) ,left cardiac work (LCW) and cardiovascular function were measured with Bioz. corn Cardio Dynamics. Results The incidence of SVR disorder in youngster and elder was higher than other subjects. The prevalence of SVR disorders was more among females than among males (P 〈0. 001 ). SVR was positively correlated with SBP, DBP, MAP, PP, LVET, body mass index (BMI), HR was negatively related to CO, CI, SV, SI, LCW, and arterial compliance ( AC ). CO and MAP were independent influencing factors with SVR. Conclusion SVR disorder is associated with age, sex, and blood pressure in people at Guangxi province and it may be a marker of vascular injury.
出处 《基础医学与临床》 CSCD 北大核心 2009年第5期484-487,共4页 Basic and Clinical Medicine
基金 国家科技部2002年社会公益研究专项重点项目(2002DIA10018)
关键词 体循环血管阻力 人群分布 心脏功能 systemic vascular resistance population distribution cardiac function
  • 相关文献

参考文献9

  • 1周晓梅,齐保申,徐成丽,韩少梅,朱广瑾.河北省体循环血管阻力异常的人群分布及相关因素[J].中国医学科学院学报,2006,28(2):249-252. 被引量:8
  • 2Hlaing WM. Differences in arterial stiffness and its correlates in triethnic young men and women [ J ]. Ethn Dis, 2006, 16(4) :837 -843.
  • 3Serraf A. Alteration of the neonatal pulmonary physiology after total cardiopulmonary bypass [ J ]. Thoral Cardiovasc Surg, 1997, 114(6):1061- 1069.
  • 4颜彦,郭兴明,肖守中.心脏功能评价指标及其检测方法进展[J].医疗卫生装备,2005,26(1):21-23. 被引量:20
  • 5Gerhardt UM, Scholler C, Bocker D, et al. Non-invasive estimation of cardiac output in critical care patients [ J ]. Clin Monit Comput, 2000, 16(4) :263 -268.
  • 6Sageman WS, Riffenburgh RH, Spiess BD. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery[ J ]. Cardiothorac Vasc Anesth, 2002, 16(1) :8 - 14.
  • 7Barin E, Haryadi DG, Schookin SI, et al. Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization[ J ]. Crit Care Med, 2000, 28 (3) : 698 - 702.
  • 8黄文红,张小忆,陆瑞昶,石秀萍,秦宗和,孙仲琴.整体阻抗法与热稀释法测定心输出量的比较[J].上海交通大学学报(医学版),2006,26(3):307-308. 被引量:3
  • 9常洪霞,倪金平.221名正常学龄儿童血流动力学参数检测[J].济宁医学院学报,2003,26(2):48-48. 被引量:2

二级参考文献18

  • 1刘春萍,周书明,程友琴.动脉顺应性及其影响因素[J].中国动脉硬化杂志,2001,9(3):275-276. 被引量:32
  • 2Fegler G Measurement of cardiac output in anaesthetized animals by a thermo-dilution method. Quarterly Journal of Experimental Physiology, 1954,39:153-64.
  • 3Nico H J, et al. Coronary Thermodilution to Assess Flow Reserve:Validation in Humans. Circulation, 2002,105(5): 2482-2486.
  • 4T Skjaerpe, L Hegrenaes, L Hatle. Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation, 1975,72:810-818.
  • 5Aasha S Gopal, MD. Assessment of Cardiac Function by Threedimensional Echocardiography Compared With Conventional Non invasive Methods.Circulation, 1995,92:842-853.
  • 6Hansen PB, Luisada AA, et al. Phococardiography as a monitor of cardiac performance during anesthesia [J]. Anesth Anolg, 1989,68:385-387.
  • 7Durand LG, Langlois YE, Lanthier T, et al.Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Med & Bio Eng & Comput, 1990,28:439.
  • 8X Shouzhong, C Shaoxi, L. Guochuan. Studying the significance of cardiac contractility variability. IEEE Eng. Med. Biol,2000,19(3):102-105.
  • 9X Shouzhong, Z Shuxian, Z Jiying, et al.Applications of cardiac contractility monitor in phonocardiogram exercise test and carotid arteriogram exercise test. J. Instrument and Meter, 2000, 21(5):123-126.
  • 10Sramek BB.Hemodynamic and pump performance monitoring by electrical bioimpedance[J].ProblRespir Care,1989,2(2):274-290.

共引文献28

同被引文献59

引证文献6

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部