摘要 通过对碳酸氢铵生产中的重要设备—碳化塔内冷却水箱损坏的原因和腐蚀机理进行分析,指出塔内冷却水箱的损坏,主要是由于NH4HCO3结晶的腐蚀、振动机械力剪切及电化学腐蚀引起.结合对碳化塔结构的改造设计。 The carbonating tower is a important equipment in the production of ammonium bicarbonate.It must be noted that the cooling water tank of carbide tower damage usually in small and middle nitrogenous fertilizer plants.The damage is caused by impulse abrasion of ammonium bicarbonate crystal,cooling tubes are sheared and electrochemical corrosion is happened.The last reason is the majorest.The electrochemical corrosion mechanism of cooling water tank and the modes of corrosion prevention are studied.
作者 杨兰
出处 《陕西师范大学学报(自然科学版)》 CAS CSCD 北大核心 1998年第S1期208-210,共3页 Journal of Shaanxi Normal University:Natural Science Edition
关键词 碳化塔 冷却水箱 腐蚀 防护 carbonating tower cooling water tank electrochemical corrosion corrosion prevention
  • 相关文献

参考文献1

  • 1陈鸿海.金属腐蚀学[M]北京理工大学出版社,1995.