摘要
高原地区的通信站由于所在地域的环境特殊,因此蓄电池组在维护中有着更多的问题。通过以常用的阀控式铅酸蓄电池为例从温度、浮充电压、供电环境等方面,对高原地区通信用蓄电池在维护和管理中遇到的问题及其原因进行了分析和探讨,并提出了相应的解决方案。
Because of the special geographical environment of communication station in plateau areas, the maintenance of battery has more problems. In this paper, these problems of maintenance and management are discussed from temperature, float voltage, power supply environment and so on, which takes VRLA battery as an example. The solutions are also presented.
出处
《通信电源技术》
2009年第2期57-58,共2页
Telecom Power Technology
关键词
蓄电池
维护管理
高原地区
battery
maintenance and management