期刊文献+

对《锁定加压钢板单骨皮质固定治疗长骨骨折髓内钉术后骨不连》一文的不同看法 被引量:5

原文传递
导出
摘要 交锁髓内钉内固定治疗长骨干骨折已被广泛应用于临床,随着应用的增加,断钉、骨不连等并发症的发生也呈日益增多的倾向。本刊2009年第1期刊登了山西医科大学第二医院王子虎等医生撰写的《锁定加压钢板单骨皮质固定治疗长骨骨折髓内钉术后骨不连》一文,文章报告对8例股骨或胫骨骨不连患者采用保留原钉、断端切新、自体髂骨植骨联合锁定加压钢板单皮质固定治疗,取得了满意的效果,为长骨干骨折髓内钉内固定后骨不连提供了一种富有成效的治疗方法。
出处 《中华创伤骨科杂志》 CAS CSCD 2009年第3期276-278,共3页 Chinese Journal of Orthopaedic Trauma
  • 相关文献

参考文献27

  • 1Brinker MR, O'Conor DP. Current concepts review: exchange nailing of ununited fractures. J Bone Joint Surg (Am) ,2007, 89: 177-188.
  • 2Klein MP, Rahn BA, Frigg R, et al. Reaming versus nonreaming in medullary nailing: interference with cortical circulation of the canine tibia. Arch Orthop Trauma Surg, 1990, 109: 314-316.
  • 3Grundnes O, Reikeras O. Acute effects of intramedullary reaming on bone blood flow in rats. Acta Orthop Scand, 1993, 64: 203-206.
  • 4Reichert IL, McCarthy ID, Hughes SP. The acute vascular response to intramedullary reaming. Microsphere estimation of blood flow in the intact ovine tibia. J Bone Joint Surg (Br), 1995, 77: 490-493.
  • 5Brinker MR, Cook SD, Dunlap JN, et al. Early changes in nutrient artery blood flow following tibial nailing with and without reaming: a preliminary study. J Orthop Trauma, 1999, 13: 129-133.
  • 6Grundnes O, Utvag SE, Reikeras O. Restoration of bone flow following fracture and reaming in rat femora. Acta Orthop Scand, 1994, 65: 185-189.
  • 7Wenisch S, Trinkaus K, Hild A, et al. Human reaming debris: a source of muhipotent stem cells. Bone, 2005, 36: 74-83.
  • 8Hoegel F, Mueller CA, Peter R, et al. Bone debris: dead matter or vital osteoblasts. J Trauma, 2004, 56: 363-367.
  • 9Frolke JP, Nulend JK, Semeins CM, et al. Viable osteoblastic potential of cortical reamings from intramedullary nailing. J Orthop Res, 2004, 22: 1271-1275.
  • 10Furlong A J, Giannoudis PV, DeBoer P, et al. Exchange nailing for femoral shaft aseptic non-union. Injury, 1999, 30: 245-249.

二级参考文献7

  • 1廖浩,方煌,陈安民,罗永湘.60例四肢长管骨骨不连的原因分析[J].中国矫形外科杂志,2005,13(16):1207-1209. 被引量:48
  • 2Mark R, Brinker, Daniel P, et al. Exchange nailing of ununited fractures [ J ]. J Bone Joint Sury ( Am ) ,2007,89 : 177 - 188.
  • 3Krettek C, Stephan C, Sehandelmaier P. The use of poller screws as blocking screws[ J]. J Bone Joint Sury(Br) ,1999,81:963 -968.
  • 4Chih-Wen H, Chi-Chuan W, Chun-Yi S,et al. Exchange nailing for tibial nonunion: emphasis on influence of a concomitant fibulotomy [ J]. Chang Gung Med J,2006,3:283 -289.
  • 5Zelle BA ,Gruen GS, Klatt B ,et al. Exchange reamed nailing for aseptic nonunion of the tibia[J]. J Trauma,2004,57 : 1053 - 1059.
  • 6Tadeusz N, Jaroslaw B, Lukasz N. Treatment of femoral shaft union disturbances with intramedullary nailing. Treatment failure [J]. Ortopedia Traumatalogia Rehabilitacja,2007,6:377 -383.
  • 7Court-Brown CM, Keating JF, Christie J,et al. Exchange intramedullary nailing,its use in aseptic tibial nonunion [J]. J Bone Joint Surg (Br) , 1995,77:407 -411.

共引文献43

同被引文献39

引证文献5

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部