对柳州电厂1号200MW机组给水全程自动调节系统进行了系统的分析、研究。提出了影响自动调节系统投入和正常使用所存在的设计、组态、硬件设备等方面的问题。给出了具体的处理方法和改进措施,并说明了自动系统的运行投入情况。
The full automatic feed-water control of No.1 200 MW units of Luizhou ThermalPower Plant is analyzed and studied in this paper. The insufficient design, configuration andhardware facilities influencing on commissioning and normal operation of the control system areproposed. An appropriate solution to the existing problems is presented with details on theoperation of the automatic device.
出处
《广西电力技术》
1998年第1期23-27,共5页
Guangxi Electric Power Technology