35 t/h 循环流化床锅炉布风板阻力特性的试验研究 被引量:3

Experimental Investigation of Air Distribution Plate Resistance of 35 t/h CFB Boiler
在线阅读 下载PDF
导出
摘要 分析了循环流化床锅炉布风板阻力的数学模型,并对HG-CFB35-3.82/450-1型锅炉布风板阻力进行了测试。 An analysis of mathematical model of air distribution plate resistance was carried out for model HG CFB35 3.82/450 1 CFB boiler with the said plate resistance being test. A regression analysis was conducted using the test results and a calculation formula obtained for determining the variation of air distribution plate resistance with air flow rate. The resistance factor obtained was designated as ζ.
出处 《电站系统工程》 1998年第1期32-33,57,共3页 Power System Engineering
关键词 布风板 阻力 循环流化床锅炉 试验 CFB air distribution plate resistance