摘要
讨论了WAMS在现有监测系统的定位,指出混合状态估计算法是系统整合的关键,同时从数据冗余度、系统可靠性、未来发展等比较两种典型的网络连接方案的优劣,并给出由传统SCADA/EMS逐步过渡到PMU/WAMS的合理方案。
The location of WAMS in the existing monitoring systems is discussed for power system. The mixed state estimation algorithm is the key of integration. On such a precondition, two typical network connection schemes are compared in term of data redundancy, system reliability and development trend. At last, the reasonable scheme transiting from traditional SCADA/ EMS to PMU/WAMS gradually is put forward.
出处
《四川电力技术》
2009年第1期91-94,共4页
Sichuan Electric Power Technology