摘要 宜兴抽水蓄能电站地下厂房结构关键部位的刚度满足厂家要求,通过厂房整体结构的模态分析,自振频率与机组的激振频率满足规范要求,另外,建立了宜兴工程厂房振动评估标准,并提出厂房结构的减振措施,从1号机现场试运行情况看,电站运行后厂房结构抗振性能良好。 The stiffness of key structures for underground powerhouse of Yixing pumped-storage power station meets the requirements of the Manufacturer. The key structure's self-vibration frequency and excitation vibration frequency are all accord with the specifications according to the integral structure model analysis of the powerhouse. The appraisal criterion of the powerhouse vibration for Yixing pumped-storage power station was set up and the damping measures for powerhouse structure was suggested. The anti-vibration performance of the powerhouse structure is good after the station was put into operation.
出处 《水力发电》 北大核心 2008年第12期54-57,共4页 Water Power
关键词 刚度 振动频率 共振 评估标准 减振措施 宜兴抽水蓄能电站 stiffness vibration frequency appraisal criterion damping measures Yixing Pumped-storage Power Station
  • 相关文献

参考文献1

  • 1马震岳,等.华东宜兴抽水蓄能电站工程地下厂房结构静、动力分析研究报告[R].大连理工大学,2005.

同被引文献20

  • 1严根华.水电站拦污栅振动特性和抗振设计研究[J].水力发电,2006,32(10):77-79. 被引量:10
  • 2张立翔.水电站拦污栅结构流固耦合振动分析[J].工程力学,1997,14(2):72-81. 被引量:3
  • 3国家质检总局,XK07 - 2005水工金属结构产品生产许可证实施细则[C].北京:中国标准出版社,2011.
  • 4America Society of Civil Engineers ( ASCE ) . Guidelines fordesign of intakes for hydroelectric plants [ C ]. NewYork,ASCE Publishers. 1995 : 469.
  • 5AHEC Indian Institute of Technology ( IIT),Civil Works-Guidelines for Hydraulic Design of SHP Projects [ C ]. Roor-kee, IIT Publishers, 2008,117.
  • 6中华人民共和国行业标准,SL74 -95水利水电工程钢闸门设计规范[C].北京:中国水利水电出版社,1995.
  • 7中华人民共和国电力行业标准,DL/T5208 -2005抽水蓄能电站设计导则[C],北京:中国电力出版社,2005.
  • 8中华人民共和国水利部,SL286 -2003水利水电工程进水口设计规范[C],北京:中国水利水电出版社,2003.
  • 9Sadmejad S A. Hydrodynamics induced vibration to trash-racks[ J] . International Journal of Engineering TransactionsB: applications, 2002,15( 4) : 357 -366.
  • 10Nascimento L P, Silva J B C,Giunta V D. Damage of hydroe-lectric power plant trash-racks due to fluid-dynamic excitingfrequencies [ J ]. Latin American Journal of Solids and Struc-tures ,2006, 3(3) :223 ~243.