期刊文献+

不同设计桩核的后牙残根核桩冠修复体的三维有限元应力分析 被引量:17

The three-dimension finite element analysis of stress in posterior residual root restored with different designed post-core crown
暂未订购
导出
摘要 目的采用三维有限元法比较不同长度和数目桩核、不同材料桩核对后牙残根桩核冠修复体牙本质应力大小及其分布的影响,探讨后牙残根桩核冠修复时合理的桩核设计及选材。方法采用CT扫描、Mimics软件及Abaqus软件建立上颌第一磨牙桩核冠的三维有限元模型。根据桩长度和数目的不同、桩核材料的不同,将上颌第一磨牙桩核冠的三维有限元模型分为相应的实验组。在模型咬合面上选取3个载荷点,分别施加80N的载荷,计算各实验组中牙本质上的Von mises应力、最大主应力、剪切应力的应力峰值及分布方式。结果在桩长度和数目不同时,随着桩长度和数目的增加,牙本质上各项应力峰值呈现不规律变化。在不同桩核材料时,随着桩核材料弹性模量的增加,牙本质上的Von mises应力、最大主应力、剪切应力峰值均减小。结论在本实验研究条件下,不同桩长度和数目、不同桩核材料对后牙残根桩核冠修复体牙本质上的应力峰值和应力分布均有影响。 Objective To analyze the stress magnitude and distribution of remaining dentin in posterior residual root restored with post-core crown by three-dimension finite element methods. The variables were number, length and material of post. Methods The models of residual root of maxillary first molar restored with post-core crown were created by CT scanning, Mimics software and Abaqus software. Different number, length and material of posts were used in the modeling. The post was cemented with zinc-phosphate cement. A load of 240 N was applied to the occlusal surface in vertical direction and tensile, shear, and Von mises stresses were calculated. Results The maximum stresses on remaining dentin changed irregularly as the number and length of post. The maximum stresses on remaining dentin decreased slightly as elastic modulus of the material of post increase. Conclusion The number, length, material of post have influence on magnitude and distribution of stress.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 2009年第1期24-28,共5页 West China Journal of Stomatology
基金 重庆医科大学校级课题基金资助项目(0200100454)
关键词 三维有限元 应力 桩核冠 three-dimension finite element stress post-core crown
  • 相关文献

参考文献18

  • 1Asmussen E, Peutzfeldt A, Sahafi A. Finite element analysis of stresses in endodontically treated, dowel-restored teeth[J]. J Prosthet Dent, 2005, 94 (4) : 321-329.
  • 2Nakamura T, Ohyama T, Waki T, et al. Stress analysis of endodontically treated anterior teeth restored with different types of pest material[J]. Dent Mater J, 2006, 25 (1): 145-150.
  • 3Reinhardt RA, Krejci RF, Pao YC, et al. Dentin stresses in postreconstructed teeth with diminishing bone support[J]. J Dent Res, 1983, 62(9) : 1002-1008.
  • 4Ko CC, Chu CS, Chung KH, et al. Effects of posts on dentin stress distribution in pulpless teeth[J]. J Prosthet Dent, 1992, 68 (3) :421-427.
  • 5Ukon S, Moroi H, Okimoto K, et al. Influence of different elastic moduli of dowel and core on stress distribution in root[J]. Dent Mater J, 2000, 19(1):50-64.
  • 6Yang HS, Lang LA, Molina A, et al. The effects of dowel design and load direction on dowel-and-core restorations[J]. J Prosthet Dent, 2001, 85 (6) : 558-567.
  • 7Albuquerque Rde C, Polleto LT, Fontana RH, et al. Stress analysis of an upper central incisor restored with different posts[J]. J Oral Rehabil, 2003, 30(9):936-943.
  • 8Holmes DC, Diaz-Arnold AM, Leary JM. Influence of post dimension on stress distribution in dentin[J]. J Prosthet Dent, 1996, 75 (2) : 140-147.
  • 9Pegoretti A, Fambri L, Zappini G, et al. Finite element analysis of a glass fibre reinforced composite endodontic post[J]. Biomaterials, 2002, 23 (13) : 2667-2682.
  • 10Kinney JH, Marshall SJ, Marshall GW. The mechanical properties of human dentin: A critical review and re-evaluation of the dental literature[J]. Crit Rev Oral Biol Med, 2003, 14(1):13-29.