期刊文献+

生物降解可吸收椎体间融合器的研究进展

原文传递
导出
摘要 自1988年Bagby用不锈钢中空状“篮子”对椎间盘源性腰痛患者进行腰椎椎体间融合并取得了成功以来.以不锈钢和钛合金材料为代表的椎间融合器已广泛应用于临床。但金属融合器存在应力遮挡,易出现融合器下沉、移位和产生伪影等,影响了融合效果及术后影像学观察。近年来,国内外学者把目光投向了生物降解材料。现将生物降解可吸收椎间融合器的研究及临床应用进展综述如下。
出处 《中国脊柱脊髓杂志》 CAS CSCD 北大核心 2009年第2期147-149,共3页 Chinese Journal of Spine and Spinal Cord
  • 相关文献

参考文献22

  • 1Van Dijk M, Smit TH, Sugihara S, et al. The effect of cage stiffness on the rate of lumbar interbody fusion:an vivo model using poly(l-lactic acid) and titanium cages[J].Spine,2002,27 (7) :682-688.
  • 2Zdeblick TA, Phillips FM. Interbody cage devices[J].Spine, 2003,28 ( 1 ) : 2-7.
  • 3李开南,刘建峰,汪学军,兰海,何智勇,熊成东,张明梅.可生物降解聚-DL-乳酸腰椎间融合器的设计及生物力学研究[J].中国脊柱脊髓杂志,2007,17(1):38-41. 被引量:7
  • 4郝勇,周跃,滕海军,曹国勇,潘勇.聚内消旋乳酸(PDLLA)椎间融合器在椎间降解情况的实验观察[J].中国矫形外科杂志,2006,14(3):206-208. 被引量:6
  • 5Lippman CR,Hajjar M,Abshire B,et al. Cervical spine fusion with bioabsorbable cages[J].Neurosurg Focus,2004,16(3):E4.
  • 6Hojo Y,Kotani Y,Ito M,et al. A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage [J].Biomaterials, 2005,26 ( 15 ) : 2643-2651.
  • 7Krijnen MR,Valstar ER,Smit TH, et al. Does bioresorbable cage material influence segment stability in spinal interbody fusion[J]?Clin Orthop Relet Res,2006,448:33-38.
  • 8Lazennec JY,Madi A,Rousseau MA, et al. Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model [J].Eur Spine J,2006,15 (10) : 1545- 1553.
  • 9Smit TH,Krijnen MR,van Dijk M,et al. Application of polylactides in spinal cages:studies in a goat model [J].Mater Sci Mater Med, 2006,17 (12) : 1237-1244.
  • 10Thomas KA,Toth JM,Crawford NR,et al. Bioresorbable poly-lactide interbody implants in an ovine anterior cervical discectomy and fusion model:three-year results[J].Spine,2008, 33(7) :734-742.

二级参考文献24

  • 1Yang XB,Roach HI,Clarke NM,et al.Human osteoprogenitor growth and differentiation on synthetic biodegradable structures after surface modification[J].Bone,2001,29(6):523-531.
  • 2Cho DY, Liau WR, Lee WY, et al. Preliminary experience using a polyetheretherketone(PEEK) cage in the treatment of cervical disc disease. Neurosurgery 2002;51 (6): 1343 - 49, discussion 1349 - 50.
  • 3Diedrich O, Perlick L, Schmitt O, et al. Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radiopaque cages. J Spinal Disord 2001; 14(6):522 - 32.
  • 4Kandziora F, Schollmeier G, Scholz M, et al. Influence of cage design on interbody fusion in a sheep cervical spine model. J Neurosurg 2002; 96(3 Suppl):321 -32.
  • 5Mcfee PC,Cunningham BW,Lee GA,et al.Revision strategies for salaging or improving failes cylindrical cages[J].Spine,1999,24(21):2147-2153.
  • 6Van M,Smit TH,Sugibara S,et al.The effect of cage stiffness on lumbar interbody fusion:An in vivo model using poly-llactic acid and titanium cages[J].Spine,2002,27 (5):682-688.
  • 7Zdeblick TA,Phillips FM.Interbody cage devices[J].Spine,2003,28 (1):2-7.
  • 8Steffen T,Tsantrizos A,Fruth I,et al.Cages:designs and coneepts[J].J Eur Spine J,2000,9 (Supp l):89-94.
  • 9Kohn J,Langer R.Bioresorbable Material[M].New York:Academic Press,1999.64-73.
  • 10Thomas KA.Biomechanics and Biomaterials.[M].Phicadelphia:WB Saunders,2001.43-51.

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部