摘要 运用传热学基本原理和经典试验换热准则式,推导得出浸油变压器平均油温升和顶油温升的计算式。并依此计算了一款三相油浸式变压器的平均油温升和顶油温升,计算结果与试验结果较为吻合,表明本计算方法在工程中应用可靠。 By utilizing the fundalmental theory of heat transfer and the classical experiment heat transfer correlation equations, the calculation methods on the mean oil temperature rise and top oil temperature rise of the oil-immersed power transformers are obtained. The calculation results and the experimental results of the mean oil and top oil temperature rises of a three-phase oil-immersed power transformer are compared and analyzed, which shows they are in relatively good agreement, so that the calculation methods are reliable for engineering applications.
作者 陈磊
出处 《河北工业科技》 CAS 2009年第1期12-14,共3页 Hebei Journal of Industrial Science and Technology
关键词 浸油变压器 平均油温升 顶油温升 计算方法 oil-immersed power transformer mean oil temperature rise top oil temperature rise calculation methods
  • 相关文献

参考文献6

  • 1LINDEN W P. An investigation of the thermal performance of an oil filled transformer winding[J]. IEEE Transon Power Delivery, 1992, 7(3): 1 347-1 355.
  • 2王秀春 俞昌铭.强油导向冷却结构变压器中导向油流量和油温升计算.中国机电工程学报,2000,20(8):14-17.
  • 3杨增军,王秀春,毛一之,智会强.高燃点油变压器散热器进出口油温差的计算方法[J].变压器,2003,40(9):18-19. 被引量:2
  • 4KARSAI K, KERENYI D, LISS L. Large Power Transformers[M]. The Nether Lands: Elserier, 1987. 41-47.
  • 5INEROPERA F P, KONX A L, MAUGHAN J R. Mixed-conveetion flow and heat transfer in the entry region of a horizontal reetangular duct[J]. Transaction of the ASME, 1987, 109(5): 434-439.
  • 6杨世民,陶文铨.传热学[M].北京:高等教育出版社,1998.