折板絮凝池流场的粒子图像测速试验研究 被引量:2

PIV monitoring of flow fields in folded plate flocculators
在线阅读 下载PDF
导出
摘要 利用粒子图像测速(PIV)技术对折板絮凝池模型中的复杂流场进行测量,分析了折板絮凝池的缩放单元和转折单元内部流场对絮凝效果的影响机制。絮凝试验表明,90°异波折板与90°同波波折板组合的浊度去除率最高,达到了97.7%,这对折板絮凝池的成本效益设计提供了理论依据。 The complex flow fields in a lab scale folded plate flocculator were monitored and measured using the particle image velocimetry (PIV) technology. The mechanisms of flow characteristics affecting flocculation in the zoom unit and the turning unit of folded plate were analyzed. Results of coagulation experiments show that the floccu- lation effectiveness was dependent on the vortex flow field of the folded plate flocculator and that the combination of 90° opposite folded plate and 90° same wave folded plate perform the best with 97.7% reduction in turbidity (from 5. 000 to 0. 117 NTU). Such findings are useful theoretical basis for design of cost effective folded plate flocculators.
出处 《环境污染与防治》 CAS CSCD 北大核心 2008年第12期47-49,共3页 Environmental Pollution & Control
基金 四川省教育厅自然重点项目(No.05204097)
关键词 折板絮凝池 粒子图像测速 流场 folded plate flocculator PIV flow fields